An automatic door may be used as equivalent facilitation when it is technically infeasible to provide sufficient strike-side clearance for code compliance, but a power-assisted door may...
Search Results "Bathtub Clearance"
-
11B-404.3 Automatic and power-assisted doors and gates
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
505.4 Height
Sufficient vertical clearance between upper and lower handrails, 9 inches (230 mm) minimum, should be provided to help prevent entrapment....
-
Transit Shelters (R308.2) (Section-by-Section Analysis)
A circular space is permitted to include knee and toe clearance. A T-shaped space is permitted to include knee and toe clearance only at the end of either the base or one arm....
-
RECOMMENDATIONS
32.7 m Vertical alignment-crest 49.8 m Recumbent bicyclists 46.7 m Refuge islands 2.5 m Bicyclists with trailers 3.0 m Signal clearance...
-
Table of Contents
CHAPTER 3: BUILDING BLOCKS 301 General 302 Floor or Ground Surfaces 303 Changes in Level 304 Turning Space 305 Clear Floor or Ground Space 306 Knee and Toe Clearance...
- Rockwood Manufacturing Company 215 Tapered Door Pull 16"
- Rockwood Manufacturing Company 215L Tapered Door Pull 28"
- PEMKO 6" Heavy Duty Threshold No. 1716
- Inclusion Solutions Model 2000 Voting Booth (Hard Curtain)
- Inclusion Solutions Model 2000 Voting Booth with Light (Hard Curtain)
- Inclusion Solutions Poll Star Voting Booth
-
11B-605.5.3 Doors
Urinal compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
11B-605.5.3 Doors
Urinal compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
- Mariak Industries Motorized Window Coverings
-
Mammography Equipment
2.It is best to position equipment to allow both front and side approaches; for some patients a side or angled approach may be better for positioning at the camera unit and plate. 3.Clearance...
-
11B-404.3 Automatic and power-assisted doors and gates
An automatic door may be used as equivalent facilitation when it is technically infeasible to provide sufficient strike-side clearance for code compliance, but a power-assisted door may...
-
Accessible Restrooms, Fitting Rooms, and Elevators
Remove trash receptacles and cigarette urns from under elevator hall call buttons and beside doors to ensure access to controls and sufficient maneuvering clearance....
-
Rough Grade Site Inspection
surface requirements along accessible routes, accessible parking and access aisles, etc. 11B-403 Verify if under-slab plumbing will provide adequate clearances...
-
Protruding Objects on Beach Access Routes
Provide and maintain clearance from natural elements around beach access routes in accordance with your unit's standards; keep in mind overhanging hazards to people who are blind or have...
-
Rough Grade Site Inspection
surface requirements along accessible routes, accessible parking and access aisles, etc. 11B-403 Verify if under-slab plumbing will provide adequate clearances...
-
Handrails Along Walking Surfaces [§403.6, §505]
Surface requirements and clearances facilitate a power grip along the length of handrails. Handrails can have circular or non-circular cross-sections, but must have rounded edges....
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position; M302 Diagnostic Equipment Used by Patients in Seated Position
The sections also include provisions for clearance in and around the base of the equipment for lift compatibility to allow the use of a patient lift by patients with disabilities for whom...
-
Work Areas [4.1.1(3)]
Recommendations: Space for turning within the work area and interior maneuvering clearances at doors, while not required, should be considered, especially where entrapment may be a concern...