Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
Search Results "Input Floor"
-
11B-608.10 Soap dish
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
Drinking Fountains for Standing Persons: ADA Standard Section 602.7
Section 602.7 covers the current ADA Standards for drinking fountains for standing persons.
-
Height: ADA Standard Section 1008.3.1.2
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground....
-
Height: ADA Standard Section 407.3.3.1
Section 407.3.3.1 covers the current ADA Standards for the height requirements of an elevators reopening device.
-
11B-809.10.7.5 Controls
Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 mm) maximum....
-
11B-809.10.7.5 Controls
Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 mm) maximum....
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground....
-
M303.2.2 Width (Section-by-Section Analysis)
In the preamble to the MDE NPRM, the Access Board sought input on whether an exception to the width requirement was needed for wheelchair spaces on raised platforms....
-
Technical Memorandum TM 2013-22 Storage (Kitchens and Kitchenettes)
Based on input from the U.S....
-
402.2 Speech-Output Enabled
Audible tones shall be permitted instead of speech output where the content of user input is not displayed as entered for security purposes, including, but not limited to, asterisks representing...
-
407.10 Privacy (Section-by-Section Analysis)
407.10 Privacy (Section-by-Section Analysis) This proposed section would require the same degree of privacy of input and output for all individuals....
-
1. Introduction
Chapter 3 describes the available data, estimates, and assumptions that are the basis for inputs used in the cost methodology described in Chapter 2 and that are applied to calculate costs...
- The United States Service Dog Registry
-
11B-407.4.6.2 Buttons
Car control buttons with floor designations shall comply with Section 11B-407.4.6.2. Exception: Reserved....
-
11B-407.4.6.2 Buttons
Car control buttons with floor designations shall comply with Section 11B-407.4.6.2. Exception: Reserved....
-
Benefits of Playing the Wave Mode in Geometry Dash
This teaches players to control their inputs carefully and develop a sense of timing....
-
Clarification on unobstructed side reach limits for interior kiosks
According to the general guidelines, the maximum high side reach should be 48 inches and the low side reach should be at least 15 inches above the finish floor....
-
1010.1.6 Thresholds
Thresholds at doorways shall not exceed ¾ inch (19.1 mm) in height above the finished floor or landing for sliding doors serving dwelling units or ½ inch (12.7 mm) above the finished floor...
-
1010.1.6 Thresholds
Thresholds at doorways shall not exceed ¾ inch (19.1 mm) in height above the finished floor or landing for sliding doors serving dwelling units or ½ inch (12.7 mm) above the finished floor...
-
11B-904.4.2 Forward approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a forward approach to the counter. [2010 ADA Standards] 904.4.2 Forward Approach....
-
Existing Site Constraints: ADA Standard Section 206.7.5
Section 206.5.1 covers scoping requirements in the most current ADA Standards for the use of platform lifts due to existing site constraints.