703.5 Visual Characters. Visual characters shall comply with 703.5. EXCEPTION: Where visual characters comply with 703.2 and are accompanied by braille complying with 703.3, they...
Search Results "Floor Designation"
-
703.5 Visual Characters
-
203.9 Employee Work Areas
Spaces and elements within employee work areas shall only be required to comply with 206.2.8, 207.1, and 215.3 and shall be designed and constructed so that individuals with disabilities...
-
10.1 Q. Is it necessary to have an accessible path of travel from a subterranean garage to single-story covered multifamily dwellings built on top of the garage?
A. Yes. The Fair Housing Act requires that there be an accessible building entrance on an accessible route. To satisfy Requirement 1 of the Guidelines, there would have to be an...
-
2.4 Patient Areas
Is there space in the waiting room for wheelchair users to sit? Is there space in the exam room for an individual using a wheelchair or other mobility aid to move and...
-
Seating [4.32.2] and Knee Clearance [4.32.3]
Seating [4.32.2] and Knee Clearance [4.32.3] Knee space at least 27 inches high is required for a depth of 19 inches. The over-the-surface reach is limited to 25 inches if at...
-
FIGURE 11A-10A KITCHEN SPECIFICATIONS
(1) 30" minimum countertop space for sink installation with removable base cabinet and finish flooring beneath the sink; 30" x 48" minimum clear floor space to allow parallel or forward...
-
7(1)(a)
(a) A clear floor space at least 30 inches by 48 inches that allows a parallel approach by a person in a wheelchair is provided at the range or cooktop and sink, and either a parallel or...
-
1133A.1 General
) (1) 30" minimum countertop space for sink installation with removable base cabinet and finish flooring beneath the sink; 30" x 48" minimum clear floor space to allow parallel...
-
Slope Meters and Levels
Corada has reviewed several models of slope meters and levels to assist accessibility surveyors in measuring slope and level changes. The following are the models that can be...
- Magnuson Group UMEA Waste Receptacles
-
1150A.1 General
Sites where either Test No. 1 or Test No. 3 is used and it is determined that an accessible route to the common (lobby) entrance is not required, at least 20 percent of the ground floor...
- Figure 1007.3.2 Golf Club Reach Range Area – Drawing from the U.S. Access Board
-
11B-233.3.1.2.6 Public housing facility site impracticality
The site impracticality tests in this section may be used to determine the number of required residential dwelling units with adaptable features in buildings without an elevator,...
-
11B-233.3.1.2.6 Public housing facility site impracticality
The site impracticality tests in this section may be used to determine the number of required residential dwelling units with adaptable features in buildings without an elevator,...
-
7(2)(b)(v)
The top of the fixture rim is a maximum height of 2'10" above the finished floor. If kneespace is provided below the vanity, the bottom of the apron is at least 2'3" above the floor....
- Magnuson Group SMOKE Waste & Ash Receptacle
- International Building Code® (IBC®)
- Landscape Forms Inc. Sort Recycling Units
-
Rough Form and Foundation Inspection
ensure correct accessible slopes (5% running slope and 2.08% cross slope). 11B-403 Verify forms for sidewalks, ramps, landings, curb ramps and clear floor...
-
Rough Form and Foundation Inspection
ensure correct accessible slopes (5% running slope and 2.08% cross slope). 11B-403 Verify forms for sidewalks, ramps, landings, curb ramps and clear floor...
-
1010.1.4 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door....
-
1010.1.4 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door....