The shower spray unit shall have an on/off control with a non-positive shut-off....
Search Results "Emergency Transportable Housing Unit"
Commonly Searched Documents
-
11B-608.6 Shower spray unit and water
-
LEGAL OPINION - U.S. DEPARTMENT OF TRANSPORTATION OFFICE of GENERAL COUNSEL on 49 CFR 37.43(a)
May 2016
-
11B-703.5.6 Height from finish floor or ground
Where provided, floor plans providing emergency procedures information in accordance with Title 19 shall not be required to comply with Section 11B-703.5.6....
-
206.3 Location
Additionally, accessible vertical interior circulation must be in the same area as stairs and escalators, not isolated in the back of the facility Note to Reader: The Department of Transportation’s...
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
11B-809.10 Toilet and bathing rooms
[See subsections ...]
-
11B-809.10.7 Water closets
Water closets required by Section 11B-809.10 shall comply with this section.
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope.
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or...
-
11B-809.10.5.2 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: 1. Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab...
-
Number of accessible cells. (Section-by-Section Analysis)
Section 232.3 provides that, where special holding cells or special housing cells are provided, at least one cell serving each purpose shall have mobility features. ...
-
Number of accessible cells. (Section-by-Section Analysis)
Section 232.3 provides that, where special holding cells or special housing cells are provided, at least one cell serving each purpose shall have mobility features....
-
§ 36.401(d)(2)(ii)
(ii) A terminal, depot, or other station used for specified public transportation, or an airport passenger terminal....
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
12. Personal Care Attendant (PCA)
While PCAs may travel with a passenger with a disability, transportation agencies are not required to provide a personal care attendant or personal care attendant services to meet the needs...
-
Other Disabilities and Multiple Disabilities
In addition to people with permanent or long-term disabilities, there are others who have temporary conditions that affect their usual abilities. Broken bones, illness, trauma, or...
-
703.5 Visual Characters
Visual characters shall comply with 703.5. EXCEPTION: Where visual characters comply with 703.2 and are accompanied by braille complying with 703.3, they shall not be required to...
-
M1
M1. If a sign is provided at the toilet room entrance (e.g. Men, Women, Boys, Girls, etc.), is a sign with raised characters and Braille mounted on the wall adjacent to the latch...
-
H12
H12. For at least one of each type of dispenser, receptacle, or equipment, is there clear floor space at least 30 inches wide x 48 inches long adjacent to the control or dispenser...
-
M13
M13. For each type of dispenser, receptacle, or equipment, is there clear floor space at least 30 inches wide x 48 inches long adjacent to the control or dispenser (positioned either...
-
H27
H27. Does this 36-inch wide stall have horizontal grab bars on both of the side partitions that are at least 36 inches long and 33 to 36 inches above the floor? [ADA Standards §...