Where audible emergency alarm systems are provided to serve the occupants of cells, visible alarms complying with Section 11B-702 shall be provided....
Search Results "Visible Signal (Elevator Landing)"
Commonly Searched Documents
-
11B-807.3.1 Alarms
- Envirobond Deters Weeds
-
Bottom Extension at Stairs: ADA Standard Section 505.10.3
Section 505.10.3 covers the current ADA Standards for the handrail extensions at the bottom of the stairs.
-
Speech Output: ADA Standard Section 707.5
Operating instructions and orientation, visible transaction prompts, user input verification, error messages, and all displayed information for full use shall be accessible to and independently...
-
11B-707.5 Speech output
Operating instructions and orientation, visible transaction prompts, user input verification, error messages, and all displayed information for full use shall be accessible to and independently...
-
A4.28.2 Audible Alarms
Audible emergency signals must have an intensity and frequency that can attract the attention of individuals who have partial hearing loss....
-
Comments from Individuals Who Are Blind or Have Low Vision (Section-by-Section Analysis)
proposed guidelines, but filed a minority report recommending that state and local governments consult with the local blind community to determine whether to provide accessible pedestrian signals...
-
3. MICROPHONE INPUTS
MICROPHONE INPUTS The quality of the signal received by users of an ALS system depends not only on the transmission characteristics to the receiver, but on the nature of the source....
- Viking E-1600A-BLT-EWP Emergency Tower Phone with Blue LED Beacon and Strobe Light
-
Public Way
Any street, alley or other parcel of land open to the outside air leading to a public street, which has been deeded, dedicated or otherwise permanently appropriated to the public for public...
-
[F] 907.5.2.3.3 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, each story that contains dwelling units and sleeping units shall be provided with the capability to support visible...
-
11B-505.10.3 Bottom extension at stairs
Extension shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
FIGURE INDEX
406.6 Diagonal or Corner Type Curb Ramps Figure 406.7 Islands in Crossings Figure 406.8 Detectable Warnings at Curb Ramps Subject to DOT Regulation 49CFR37.21 Figure 407.2.2.2 Visible...
-
11B-411.4.11.3 Duration
Floor destination characters shall be displayed upon elevator car arrival at the input floor and shall not extinguish until the elevator car arrives at the destination floor....
-
4.28.3(8)
(8) No place in common corridors or hallways in which visual alarm signalling appliances are required shall be more than 50 ft (15 m) from the signal....
-
SUMMARY
Careful evaluation of every pedestrian signal installation is needed to assure that it meets the goals of providing accurate and helpful information to pedestrians who have vision impairments...
-
11B-809.5.2.1 Activation
All visible alarm appliances provided within the residential dwelling unit for smoke detection notification shall be activated upon smoke detection. ...
-
11B-809.5.2.1 Activation
All visible alarm appliances provided within the residential dwelling unit for smoke detection notification shall be activated upon smoke detection....
-
Use Zone
designated by ASTM F 1487 (incorporated by reference, see “Referenced Standards” in Chapter 1) for unrestricted circulation around the play equipment and where it is predicted that a user would land...
-
Attachment J
The elevator is inaccessible because, although emergency communications are provided, they were programmed to a non-working number. ...
-
Public Right-of-Way
Public land acquired for or dedicated to transportation purposes, or other land where there is a legally established right for use by the public for transportation purposes....
-
Determine All Your Evacuation Options and Prioritize Them
Often incorporated into the design of fire stair landings, but can be provided in other recognized locations meeting design specifications, including those for fire and smoke protection....
-
§1193.51(b) Connection point for external audio processing devices
Products providing auditory output shall provide the auditory signal at a standard signal level through an industry standard connector....
-
1009.3 Stairways
egress, a stairway between stories shall have a clear width of 48 inches (1219 mm) minimum between handrails and shall either incorporate an area of refuge within an enlarged floor-level landing...