Because it may be difficult for a person with a disability to open a door against the resistance offered by a closer, it is important that the closing action be slow enough to allow entry...
Search Results "Ramped Entry"
-
Door Closers [4.13.10]
-
Press Boxes [§206.2.7]
field or assembly area is no more than 500 sq. ft. if press boxes are either: free-standing and elevated above grade at least 12’ or located in bleachers with points of entry...
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....
-
11B-208.3.3.2
An accessible route from the residential dwelling unit's primary entry door to the vehicular entrance at the garage....
-
DETECTABLE WARNING
Curb ramps remove the needed cues for persons with visual impairments; detectable warnings have been developed as a replacement cue and warning to indicate the presence of a vehicular way...
-
DETECTABLE WARNING
Curb ramps remove the needed cues for persons with visual impairments; detectable warnings have been developed as a replacement cue and warning to indicate the presence of a vehicular way...
-
Effect on Removal of Barriers in Existing Facilities: ADA Standard Section 101.2
Section 101.2 of the ADA Standards covers the effects of the removal of barriers in existing facilities.
-
Handrails Along Walkways
The 1991 Standards do not contain any technical requirement for handrails provided along walkways that are not ramps....
-
R409.4 Height
Top of gripping surfaces of handrails shall be 865 mm (2.8 ft) minimum and 965 mm (3.2 ft) maximum vertically above walking surfaces, ramp surfaces, and stair nosings....
-
11B-407.2.3.1 Floor designation
A raised star, placed to the left of the floor designation, shall be provided on both jambs at the main entry level. ...
-
11B-608.2.1 Transfer type shower compartments
shower compartments shall be 36 inches (914 mm) by 36 inches (914 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (914 mm) wide minimum entry...
-
1133B.5.4.5
SECTION 1133B GENERAL ACCESSIBILITY FOR ENTRANCES, EXITS AND PATHS OF TRAVEL 1133B.5 Ramps. 1133B.5.4.5 Landing width. ...
-
EXIT
Exit components include exterior exit doors at the level of exit discharge, interior exit stairways, interior exit ramps, exit passageways, exterior exit stairways and exterior exit ramps...
-
Changes in Level [4.5.2]
Changes in level greater than ½ inch where the slope is more than 5% must be treated as a curb ramp [4.7] or ramp [4.8]....
-
4.3.8 CHANGES IN LEVELS
If an accessible route has changes in level greater than 1/2 in (13 mm), then a curb ramp, ramp, elevator, or platform lift shall be provided that complies with 4.7, 4.8, 4.10, or 4.11,...
-
Door King Inc. 1837 PC Programmable IM Server Overview
Requires the Registered User plan or above. Login!
-
11B-804.2.1 Pass through kitchen
Pass through kitchens shall have two entries. FIGURE 11B-804.2.1 PASS THROUGH KITCHENS...
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....
-
11B-208.3.3.2
An accessible route from the residential dwelling unit's primary entry door to the vehicular entrance at the garage....
-
407.2.3.1 Floor Designation
A tactile star shall be provided on both jambs at the main entry level....
-
4.13.6 MANEUVERING CLEARANCES AT DOORS
Entry doors to acute care hospital bedrooms for in-patients shall be exempted from the requirement for space at the latch side of the door (see dimension "x" in Fig. 25) if the door is at...
-
Q17. Does the ADA require that service animals be certified as service animals?
Covered entities may not require documentation, such as proof that the animal has been certified, trained, or licensed as a service animal, as a condition for entry....
-
E. GRIEVANCE PROCEDURE
Within three (3) months of the entry of this Consent Decree, the County will adopt the attached ADA Grievance Procedure, Attachment C, distribute it to all of its agencies, post it on its...
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area at the exterior side of the primary entry door and any required exit doors shall comply with Section 1126A....