Any part of an accessible route with a slope greater than 1:20 shall be considered a ramp and shall comply with 4.8.
Search Results "Floor Surface"
Commonly Searched Documents
-
4.8.1* GENERAL
-
1017.7 Slopes
This section contains technical requirements for the maximum running slope and segment length (1017.7.1) and cross slope (1017.7.2) of trails.
-
3.1.3 Slope of Vehicle Parking Spurs
The slope of parking spurs shall comply with applicable provisions of section 3.1.3.
-
5.1 GENERAL
In addition to the requirements of 4.1 to 4.33, the design of at least 5 percent of all fixed seating or tables in a restaurant or cafeteria shall comply with 4.32. Access aisles...
-
1017.7.1 Maximum Running Slope and Segment Length
This section requires that not more than 30 percent of the total length of a trail have a running slope steeper than 1:12 (8.33%), and that the running slope of any segment of a...
-
1016.7 Slopes
The slopes of outdoor recreation access routes shall comply with 1016.7.
-
11B-406.5.7 Cross slope
The cross slope of curb ramps and blended transitions shall be 1:48 maximum.
-
11B-1009.2.3 Clear deck space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat. The space shall be 36 inches (914 mm) wide minimum and shall extend forward...
-
11B-1009.2.3 Clear deck space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat. The space shall be 36 inches (914 mm) wide minimum and shall extend forward...
-
11B-406.5.7 Cross slope
The cross slope of curb ramps and blended transitions shall be 1:48 maximum.
-
4.9.4 HANDRAILS
At the top, the extension shall be parallel with the floor or ground surface....
-
BABY CHANGE
Hello: I am the first person to watch the vedio
-
11B-805.2.2 Beds
[2010 ADAS] 805.3 Clear Floor or Ground Space. A clear floor space complying with 305 shall be provided on each side of the bed....
-
11B-805.2.2 Beds
[2010 ADAS] 805.3 Clear Floor or Ground Space. A clear floor space complying with 305 shall be provided on each side of the bed....
-
11B-805.2.2 Beds
[2010 ADA Standards] 805.3 Clear Floor or Ground Space. A clear floor space complying with 305 shall be provided on each side of the bed....
-
Sec. 469.104. Failure to Submit Plans and Specifications.
The commission shall report to the Texas Board of Architectural Examiners, the Texas Board of Professional Engineers, or another appropriate licensing authority the failure of any...
-
A4.33.2 Size of Wheelchair Locations
Spaces large enough for two wheelchairs allow people who are coming to a performance together to sit together.
-
Side Approach
Side Approach Clear space for a side approach is specified for units that are free-standing or built-in. Space must be available so that a person using a wheelchair can align...
-
A4.33.2 SIZE OF WHEELCHAIR LOCATIONS
Spaces large enough for two wheelchairs allow people who are coming to a performance together to sit together.
-
Accessible Sidewalks 2: Pedestrians with Ambulatory Impairments
Requires the Registered User plan or above. Login!
-
M13
For each type of dispenser, receptacle, or equipment, is there clear floor space at least 30 inches wide x 48 inches long adjacent to the control or dispenser (positioned either parallel...
- Smith Carrel Hi-Lo Study Carrel - "The Original"
-
H12
For at least one of each type of dispenser, receptacle, or equipment, is there clear floor space at least 30 inches wide x 48 inches long adjacent to the control or dispenser (positioned...
-
M305.3.2 Height (Section-by-Section Analysis)
For horizontal supports, the MDE NPRM proposed a gripping surface height of 34 inches minimum and 38 inches maximum above the standing surface....