Where a sign or other obstruction is mounted between posts or pylons and the clear distance between the posts or pylons is greater than 12 inches (305 mm), the lowest edge of such sign or...
Search Results "Clear"
-
11B-307.3 Post-mounted objects
-
Edge Protection: ADA Standard Section 1005.3
platform 12 inches (305 mm) where the 34 inch (865 mm) high railing is provided is an alternative design, permitting individuals using wheelchairs or other mobility devices to pull into a clear...
-
11B-307.3 Post-mounted objects
Where a sign or other obstruction is mounted between posts or pylons and the clear distance between the posts or pylons is greater than 12 inches (305 mm), the lowest edge of such sign or...
-
Post-Mounted Objects: ADA Standard Section 307.3
Section 307.3 covers the current ADA Standards for the protrusion limits for post-mounted objects.
-
Trailhead Signs
Locate trailhead information signs centered at the back of a 30- by 48-inch (760- by 1,220-millimeter) -minimum clear floor or ground space....
-
Designing Accessible Data Centers and IT Infrastructure: ADA Compliance for Enterprise Environments
Clear Layouts for Everyone Accessible data centers need sufficient aisle width and reachable equipment heights....
-
Fire Rings, Grills, Fireplaces, and Wood Stoves
The clear space must extend at least 48 inches (1,220 millimeters) out from the feature and be at least 48 inches (1,220 millimeters) wide....
-
1133A.2.1, Item 3
All other kitchen designs shall provide a minimum clear width of at least 48 inches (1219 mm). (See Figure 11A-10A)....
-
§ 36.303(f)(2)
(2) A clear, sufficiently large, and sharply delineated picture of the interpreter's head and the participating individual's head, arms, hands, and fingers, regardless of his body position...
-
§ 35.160(d)(2)
(2) A clear, sufficiently large, and sharply delineated picture of the interpreter's head and the participating individual's head, arms, hands, and fingers, regardless of his body position...
-
11B-406.5.2 Width
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 48 inches (1219 mm) minimum....
-
5.3.5 Doors
The door shall not swing into or otherwise obstruct the clear floor or ground space required by 5.3.2.1....
-
11B-406.5.2 Width
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 48 inches (1219 mm) minimum....
-
1133A.2.1, Item 3
All other kitchen designs shall provide a minimum clear width of at least 48 inches (1219 mm). (See Figure 11A-10A)....
-
11B-406.5.2 Width
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 48 inches (1219 mm) minimum....
-
Common Requirements (R304.5) (Section-by-Section Analysis)
Common Requirements (R304.5) (Section-by-Section Analysis) The clear width of curb ramp runs (excluding flared sides), blended transitions, and turning spaces must be 1.2 meters (4 feet...
-
Trash, Recycling, and Other Essential Containers
The clear space may overlap the clear space for adjacent containers. It must be adjacent to and may overlap the outdoor recreation access route....
-
Gardenscapes Hack Free Stars and Coins Mod SHOCKED
Because here’s the secret: more efficient moves = more likely to earn extra stars. 2) Aim for the “combo momentum,” not random clearing At the start, I used to clear whatever was...
-
405.7.4 Change in Direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
707.7.1 Visibility
The display screen shall be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the machine....
-
405.7.4 Change in Direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum....
-
11B-904.4.2 Forward approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a forward approach to the counter. [2010 ADAS] 904.4.2 Forward Approach. ...