This route must have no steps or steeply sloped surfaces and it must have a firm, stable, slip-resistant surface....
Search Results "Ramp Slope"
-
Accessible Parking
-
1132A.4.1, Item 2
Thresholds with a change in height between ¼ inch (6.35 mm) and 3/4 inch (19.05 mm) shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)...
-
11B-404.2.5 Thresholds
[2010 ADA Standards] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required...
-
11B-404.2.5 Thresholds
[2010 ADA Standards] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required...
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
Clear Deck Space: ADA Standard Section 1009.4.1
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-206.2.3.2 Distance to Elevators
new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via ramp...
-
11B-206.7.5 Existing site constraints
Platform lifts shall be permitted where existing exterior site constraints make use of a ramp or elevator infeasible. Advisory 11B-206.7.5 Existing site constraints....
-
11B-206.7.5 Existing site constraints
Platform lifts shall be permitted where existing exterior site constraints make use of a ramp or elevator infeasible. Advisory 11B-206.7.5 Existing site constraints....
-
11B-206.2.3.2 Distance to Elevators
new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via ramp...
-
1013.4 Raised character and braille exit signs
Each exit door that is required to comply with Section 1013.1, and that leads directly to a grade-level exterior exit by means of a stairway or ramp shall be identified by a tactile exit...
-
1017.10 Trailhead Signs
Typical and maximum running slope; and 5. Typical and maximum cross slope....
-
1017.10 Trailhead Signs
Typical and maximum running slope; and 5. Typical and maximum cross slope....
-
Auditorium accessible seating
However, there are not any shown accessible access routes to this level via ramps or doors....
-
1014.3 Floor
This section requires the floor surface within camp shelters to be firm and stable and to slope not steeper than 1:48 in any direction....
-
11B-403.7 Continuous gradient
The slope of the resting area in all directions shall be 1:48 maximum. ETA Editor's Note CBC requirement 11B-403.7 is not present in the 2010 ADA Standards....
-
11B-403.7 Continuous gradient
The slope of the resting area in all directions shall be 1:48 maximum. ETA Editor's Note CBC requirement 11B-403.7 is not present in the 2010 ADA Standards....
-
11B-705.1.1.4 Resiliency
Exception: Detectable warning surfaces at curb ramps, islands or cut-through medians shall not be required to comply with Section 11B-705.1.1.4....
-
11B-705.1.1.4 Resiliency
Exception: Detectable warning surfaces at curb ramps, islands or cut-through medians shall not be required to comply with Section 11B-705.1.1.4....
-
1010.1.6 Thresholds
Raised thresholds and floor level changes greater than ¼ inch (6.4 mm) at doorways shall be beveled with a slope not greater than one unit vertical in two units horizontal (50-percent slope...
-
1010.1.6 Thresholds
Raised thresholds and floor level changes greater than ¼ inch (6.4 mm) at doorways shall be beveled with a slope not greater than one unit vertical in two units horizontal (50-percent slope...
-
11B-233.3.1.2.6.3 Test number two, site analysis test
Calculate the percentage of the total buildable area of the undisturbed site with a natural grade less than 10 percent slope....