For each elevated ramp run: 12-inch (305 mm) maximum rise 1:12 maximum slope 36-inch (915 mm) minimum clear width ...
Search Results "Clear Width"
-
Ramps
-
1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
Technical Requirements [1018 and 1018.1, Exception 3]
The technical requirements for beach access routes include specific provisions for connections, the surface, clear width, obstacles, openings, running slope, cross slope, resting intervals...
-
2.6 Passing Spaces
ORARs with a clear width less than 60 inches (1525 mm) shall provide passing spaces complying with 2.6 at intervals of 200 feet (61 m) maximum....
-
Passing Spaces [1016.4]
Where the clear width of an ORAR is less than 60 inches, passing spaces must be provided at intervals of at least 200 feet....
-
1002.4.4.2 Side Entry
The amount of clear space needed within the ride, and the size and position of the opening are interrelated....
-
11B-1002.4.4.2 Side entry
The amount of clear space needed within the ride, and the size and position of the opening are interrelated....
-
1002.4.4.2 Side Entry
The amount of clear space needed within the ride, and the size and position of the opening are interrelated....
-
1002.4.4.2 Side Entry
The amount of clear space needed within the ride, and the size and position of the opening are interrelated....
-
11B-1002.4.4.2 Side entry
The amount of clear space needed within the ride, and the size and position of the opening are interrelated....
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
11B-1002.4.4.2 Side entry
The amount of clear space needed within the ride, and the size and position of the opening are interrelated....
-
11B-1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
11B-1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
11B-1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
R409.10 Handrail Extensions
In alterations where handrail extensions would reduce the clear width required for pedestrian access routes, handrail extensions shall not be required....
-
Station 1-Physical Characteristics
Tire or wheel width. Tire type (pneumatic, polyurethane, solid rubber, etc.)...
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
10.2.1(1)
(1) Where new bus stop pads are constructed at bus stops, bays or other areas where a lift or ramp is to be deployed, they shall have a firm, stable surface; a minimum clear length of 96...
-
11B-608.2.2 Standard roll-in type shower compartments