Housing facilities that are provided by or on behalf of a place of education, with residential dwelling units leased on a year round basis exclusively to graduate students or faculty, and...
Search Results "Residential Dwelling Unit for Sale"
Commonly Searched Documents
-
11B-233.3.6 Graduate student and faculty housing at a place of education
-
Overlap: ADA Standard Section 604.3.2
Section 604.3.2 covers the current ADA Standards for overlapping clearances in the water closet clear floor space.
-
4.34.1 GENERAL
The requirements of 4.34 apply to dwelling units required to be accessible by 4.1....
-
206.7.6 Guest Rooms and Residential Dwelling Units, F206.7.6 Guest Rooms and Residential Dwelling Units
206.7.6 Guest Rooms and Residential Dwelling Units F206.7.6 Guest Rooms and Residential Dwelling Units The final rule edits the references in these sections to the technical requirements...
-
208.3.2 Residential Facilities, F208.3.2 Residential Facilities
208.3.2 Residential Facilities F208.3.2 Residential Facilities The final rule edits the references in these sections to the technical requirements for residential dwelling units with...
-
11B-233.3.4.2 Alterations to individual residential dwelling units
of Section 11B-233.3.1 shall apply to the altered residential dwelling units until the total number of residential dwelling units complies with the minimum number required by Sections 11B...
-
11B-809.8.4 Door signal devices
Every primary entrance to a residential dwelling unit with adaptable features shall be provided with a door buzzer, bell, chime or equivalent....
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
In elevator buildings, public housing facilities with multi-story residential dwelling units shall comply with the following: The primary entry of the multi-story residential...
-
233.3 Residential Dwelling Units Provided by Entities Not Subject to HUD Section 504 Regulations
233.3 Residential Dwelling Units Provided by Entities Not Subject to HUD Section 504 Regulations....
-
Section 35.151(j) Residential housing for sale to individual owners
The 2010 Standards contain scoping and technical standards for residential dwelling units....
-
Residential Facilities [§208.2.3, §208.3.2]
Residential Facilities [§208.2.3, §208.3.2] Accessible parking at residential facilities is based on the ratio of parking spaces to dwelling units. ...
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
In non-elevator buildings, a minimum of 10 percent but not less than one of the ground floor multi-story residential dwelling units shall be calculated using the total number of multi-story...
-
11B-604.4 Seats
In residential dwelling units, the height of water closets shall be permitted to be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum above the finish floor measured to the top of...
-
233.3.5 Dispersion
Residential dwelling units required to provide mobility features complying with 809.2 through 809.4 and residential dwelling units required to provide communication features complying with...
-
233.3.5 Dispersion
Residential dwelling units required to provide mobility features complying with 809.2 through 809.4 and residential dwelling units required to provide communication features complying with...
-
233.3 Residential Dwelling Units Provided by Entities Not Subject to HUD Section 504 Regulations
Facilities with residential dwelling units provided by entities not subject to regulations issued by the Department of Housing and Urban Development (HUD) under Section 504 of the Rehabilitation...
-
Alterations to Vacated Buildings: ADA Standard Section 233.3.4.1
Section 233.3.4.1 covers scoping requirements in the current ADA Standards for alterations to vacated buildings.
-
809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
11B-809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
11B-809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
11B-809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
11B-233.3.1.2 Residential dwelling units with adaptable features
In public housing facilities with residential dwelling units, adaptable residential dwelling units complying with Chapter 11A, Division IV – Dwelling Unit Features shall be provided as required...