The bench shall provide for back support or shall be affixed to a wall....
Search Results "Positioning Support"
-
903.4 Back Support
-
11B-307.4.1 Guy braces
Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
-
11B-307.4.1 Guy braces
Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
-
M305.2.2 Length
The length of transfer supports shall comply with M305.2.2.1 or M305.2.2.2....
- Midmark 647 Barrier-Free® Power Podiatry Procedures Chair
-
Q3. Are emotional support, therapy, comfort, or companion animals considered service animals under the ADA?
Are emotional support, therapy, comfort, or companion animals considered service animals under the ADA? A. No. ...
-
M305.2.7 Clearance (Section-by-Section Analysis)
In the MDE NPRM, the Access Board did not provide any specific requirements for clearances around the transfer support....
-
1008.4.5 Transfer Supports
Where play components require transfer to entry points or seats, at least one means of support for transferring shall be provided....
-
1008.4.5 Transfer Supports
Where play components require transfer to entry points or seats, at least one means of support for transferring shall be provided....
-
11B-407.4.8 Car position indicators
Audible and visible car position indicators shall be provided in elevator cars....
-
11B-407.4.8 Car position indicators
Audible and visible car position indicators shall be provided in elevator cars....
-
Figure M5: Overview of M303 Diagnostic Equipment for Use by a Patient While Seated in a Wheelchair and 304 Diagnostic Equipment for Use by a Patient in a Standing Position (Mammography Machine Example)
Where the primary use of the equipment supports more than one patient position, it must comply with the requirements for each use. ...
- Brewer AssistPRO™ Power Procedure Table
- Figure 903.4 Bench Back Support – Drawing from the U.S. Access Board
-
5.4.11 Transfer Support Structural Strength Recommendations for M301 and M302
5.4.11 Transfer Support Structural Strength Recommendations for M301 and M302 Description: Transfer supports and their connections must be capable of resisting sufficient vertical and...
-
M305.2.3 Fittings
Transfer supports shall not rotate within their fittings....
-
Medical Diagnostic Equipment Accessibility Standards Sub Committee Recommendations Stretcher Final Report
Chart from Proposed Accessibility Standards for Medical Diagnostics Equipment Appendix to part 1195 Patient Positions Equipment Designed to Support Equipment Features...
-
M305.2.8 Fittings
Transfer supports shall not rotate within their fittings when in place for transfer....
-
602.4 Alternate Formats for Non-electronic Support Documentation
Alternate formats usable by individuals who are blind or have low vision shall be provided upon request for support documentation in non-electronic formats....
-
M305.2.7 Clearance
Clearance between the transfer support gripping surface and adjacent surfaces or obstructions shall be 1 ½ inches (38 mm) minimum....
-
M305.2.6 Gripping Surfaces (Section-by-Section Analysis)
The proposed rule did not provide any specific requirements regarding gripping surfaces on transfer supports....
-
M305.2.1 Location
Transfer supports shall comply with M305.2.1.1 or M305.2.1.2 and shall be located 1 ½ inches (38 mm) maximum measured horizontally from the plane defined by the nearest edge of the transfer...
-
M305.2.5 Surface Hazards (Section-by-Section Analysis)
The proposed rule did not provide any specific restrictions regarding surface hazards around the transfer supports....
-
602.4 Alternate Formats for Non-Electronic Support Documentation
Where support documentation is only provided in non-electronic formats, alternate formats usable by individuals with disabilities shall be provided upon request....