E102.6 ISO (Section-by-Section Analysis) ISO 14289-1 (2012), Document management applications — Electronic document file format enhancement for accessibility — Part 1: Use of ISO...
Search Results "Open Doors Organization"
-
E102.6 ISO (Section-by-Section Analysis)
-
Can elevator doors close sooner than the minimum opening time specified when users activate door close?
User activation of door close (or automatic operation) cannot reduce the initial opening time of doors (3 seconds minimum) or the minimum door signal timing (based on 1.5/ ft/s travel speed...
-
11B-409.3.1 Power operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19....
-
11B-409.3.1 Power operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19....
-
11B-504.3 Open risers
Open risers are not permitted. Exceptions: On exterior stairways, an opening of not more than ½ inch (12.7 mm) may be permitted between the base of the riser and the tread....
-
11B-504.3 Open risers
Open risers are not permitted. Exceptions: 1. ...
-
11B-504.3 Open risers
Open risers are not permitted. Exceptions: 1. ...
-
2.8 Openings
Openings in the surface of ORARs shall be small enough to prevent passage of a 1/2 inch (13 mm) diameter sphere....
-
11B-404.2 Manual doors, doorways, and manual gates
Manual doors and doorways and manual gates intended for user passage shall comply with Section 11B-404.2....
-
11B-404.2 Manual doors, doorways, and manual gates
Manual doors and doorways and manual gates intended for user passage shall comply with Section 11B-404.2....
-
Door and Signal Timing: ADA Standard Section 407.3.4
Section 407.3.4 covers the current ADA Standards for door and signal timing of elevator reopening devices.
-
Power Operation: ADA Standard Section 409.3.1
Section 409.3.1 covers the current ADA Standards for the power operation of private residence elevator doors.
-
Door Swing: ADA Standard Section 304.4
Section 304.4 covers the current ADA Standards for doors swinging into turning spaces.
-
11B-411.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-411.3....
-
11B-411.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-411.3....
- Open Sesame Remote Controlled Low-Voltage Door System
-
§ 36.303(g)(1)(viii) Open movie captioning
(viii) Open movie captioning means the written on-screen display of a movie's dialogue and non-speech information, such as music, the identity of the character who is speaking, and other...
-
§ 36.303(g)(1)(viii) Open movie captioning
(viii) Open movie captioning means the written on-screen display of a movie's dialogue and non-speech information, such as music, the identity of the character who is speaking, and other...
-
Full-Powered Automatic Doors and Gates [§404.3]
Full-Powered Automatic Doors and Gates [§404.3] Full-powered automatic doors and gates are often found in grocery and retail stores, hotels, and airports to ease passage with shopping...
-
Must elevator doors remain open for 20 seconds?
LULA swing doors, private residence elevator doors, and platform lift gates and doors must remain open for 20 seconds minimum....
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...