Symbols of accessibility and their background shall have a non-glare finish....
Search Results "Non-Elevator Building"
-
Finish and Contrast: ADA Standard Section 703.7.1
-
11B-703.7.1 Finish and contrast
Symbols of accessibility and their background shall have a non-glare finish....
-
11B-703.7.1 Finish and contrast
Symbols of accessibility and their background shall have a non-glare finish....
-
217.4.3 Building Requirement
217.4.3 Building Requirement. TTYs in public buildings shall be provided in accordance with 217.4.3.1. TTYs in private buildings shall be provided in accordance with 217.4.3.2....
-
III-7.3130 General exceptions
1) Observation galleries used primarily for security purposes; or 2) Nonoccupiable spaces accessed only by ladders, crawl spaces, very narrow passageways, or freight (nonpassenger) elevators...
-
217.4.3 Building Requirement
TTYs in public buildings shall be provided in accordance with 217.4.3.1. TTYs in private buildings shall be provided in accordance with 217.4.3.2....
-
1.9.1.1 Application
Publicly funded buildings, structures, sidewalks, curbs and related facilities shall be accessible to and usable by persons with disabilities as follows: Advisory 1.9.1.1 Application...
-
1.9.1.1 Application
Publicly funded buildings, structures, sidewalks, curbs and related facilities shall be accessible to and usable by persons with disabilities as follows: Advisory 1.9.1.1 Application...
-
F217.4.3 Building Requirement
Where at least one public pay telephone is provided in a public use area of a building, at least one public TTY shall be provided in the building in a public use area....
-
Common Use Areas in Residential Facilities—Section 203.8 of the 2010 Standards
The only exception would be common use areas provided on upper stories of a non-elevator building provided the same common use areas are provided on the ground floor....
-
1009.2.1 Elevators required
be an elevator complying with Section 1009.4....
-
SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL
[See subsections ...]
-
SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL
[See subsections ...]
-
Location: ADA Standard Section 407.4.6.1
Section 407.4.6.1 covers the current ADA Standards for the location of elevator car controls.
-
1009.6.2 Stairway or elevator access
Every required area of refuge shall have direct access to a stairway complying with Sections 1009.3 and 1023 or an elevator complying with Section 1009.4....
-
Buttons: ADA Standard Section 407.4.6.2
Section 407.4.6.2 covers the current ADA Standards for the elevator car control buttons.
- Federal Elevator Systems, Inc. Showroom
-
1009.2.1 Elevators required
stories above the level of exit discharge, not less than one required accessible means of egress shall include an elevator complying with Section 1009.4....
-
Qualified Historic Building or Facility
Qualified Historic Building or Facility....
-
Alterations to Vacated Buildings: ADA Standard Section 233.3.4.1
Section 233.3.4.1 covers scoping requirements in the current ADA Standards for alterations to vacated buildings.
-
QUALIFIED HISTORIC BUILDING OR FACILITY
QUALIFIED HISTORIC BUILDING OR FACILITY....
-
11B-703.8.12 Protective covering
Where a protective layer is placed over VMS characters through which the VMS characters must be viewed, the protective covering shall have a non-glare finish....
-
11B-703.8.12 Protective covering
Where a protective layer is placed over VMS characters through which the VMS characters must be viewed, the protective covering shall have a non-glare finish....
-
4(3)
(3) In multistory dwelling units in buildings with elevators, the story of the unit that is served by the building elevator (a) is the primary entry to the unit; (b) complies with Requirements...