The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
- Pilot Rock Accessible Grills and Fire Rings
-
Section 36.405 Alterations: Historic Preservation (Section-By-Section Analysis and Response to Comments)
Preservation (Section-By-Section Analysis and Response to Comments) Section 36.405 gives effect to the intent of Congress, expressed in section 504(c) of the Act, that this part recognize the national...
-
Activation: ADA Standard Section 809.5.1.2
All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the portion...
-
11B-809.5.1.2 Activation
All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the portion...
-
907.5.2.3.3 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, each story that contains dwelling units and sleeping units shall be provided with the capability to support...
-
6.12 Handrails and Edge Protection
Where elevated dune crossings or dune crossings steeper than 1:20 (5 percent) are part of beach access routes, handrails complying with ABAAS section 505 and edge protection complying...
-
907.5.2.3.4 Groups R-2.1, R-3.1 and R-4
Protective social care facilities which house persons who are hearing impaired, shall be provided with notification appliances for the hearing impaired installed in accordance with NFPA...
-
11B-809.5.1.1 Alarm appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with Chapter 9, Section 907.5.2.3.3....
-
405.9.2 Curb or Barrier
A curb or barrier shall be provided that prevents the passage of a 4 inch (100 mm) diameter sphere, where any portion of the sphere is within 4 inches (100 mm) of the finish floor or...
-
R407.9.2 Curb or Barrier
R407.9.2 Curb or Barrier. A curb or barrier shall be provided that prevents the passage of a 100 mm (4 in) diameter sphere, where any portion of the sphere is within 100 mm (4 in) of...
-
405.9.2 Curb or Barrier
A curb or barrier shall be provided that prevents the passage of a 4 inch (100 mm) diameter sphere, where any portion of the sphere is within 4 inches (100 mm) of the finish floor or...
-
F202.6.5.2 Fire Alarms
Fire alarms shall comply with F215. EXCEPTION: Fire alarms shall not be required to comply with 702 where existing power sources must be upgraded to meet the requirement....
-
Evan Terry Associates Barrier Management Systems
Barrier Management Systems Evan Terry Associates, LLC concentrates a significant portion of its resources to the study and application of the facilities and program access requirements...
-
1010 Shooting Facilities with Firing Positions
[See subsections ...]
-
F243 Shooting Facilities with Firing Positions
[See subsections ...]
-
1010 Shooting Facilities with Firing Positions
[See subsections ...]
-
243 Shooting Facilities with Firing Positions
[See subsections ...]
-
ANSI
[DSA-AC] The American National Standards Institute....
-
12131(1)(C)
(C) the National Railroad Passenger Corporation, and any commuter authority (as defined in section 24102(4) of title 49)....
-
Alarm Appliances: ADA Standard Section 809.5.1.1
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....