Lavatories must comply with the technical requirements for lavatories in section 606 of the ABA Standards....
Search Results "Lavatory Centerline"
-
Sinks [F212.3, Exception 2]
- Just Manufacturing Oval Lavatory Group Drop-in Sink with Overflow
-
Clear Floor Space [4.19.3]
Recommendations:Consider locating towel dispensers within reach from the lavatory so that people can dry their hands before maneuvering wheelchairs....
-
Sinks [4.24]
Sinks [4.24] ADAAG provides technical specifications for both "lavatories" and "sinks."...
- Willoughby Industries CEL-Multi-Station Lavatory Series
-
Link to Cut Sheet Revised.
Thanks so much for catching this, Michelle! The link to the cut sheet has been updated.
-
Link Broken
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
-
Zurn Model Z1209 Vertical Offset Siphon Jet Water Closet Support System
Requires the Premium User plan or above. (Login or upgrade your account!)
-
M9
Does the lavatory have at least a 29-inch-high clearance under the front edge and the top of the rim no more than 34 inches above the floor?...
-
1134A.8, Item 5
The finished floor beneath the lavatory shall be extended to the wall....
-
1134A.8, Item 5
The finished floor beneath the lavatory shall be extended to the wall....
-
4.19.5 Faucets
Faucets shall comply with 4.27.4. Lever-operated, push-type, and electronically controlled mechanisms are examples of acceptable designs. If self-closing valves are used the faucet...
-
Faucets [4.19.5]
Faucets [4.19.5] Faucets must: be within reach range be automatic or, if hand operated, operable with one hand operate without tight grasping, pinching,...
-
4.19.5 FAUCETS
Faucets shall comply with 4.27.4. Lever-operated, push-type, and electronically controlled mechanisms are examples of acceptable designs. Self-closing valves are allowed if the...
-
Water Closet Clearance
The 1991 Standards allow the nearest side of a lavatory to be placed 18 inches minimum from the water closet centerline and 36 inches minimum from the side wall adjacent to the water closet...
-
I. Public Toilet Rooms
Public Toilet Rooms: (1) In all public and common use toilet rooms throughout the Hotel and the Tower, Defendants will provide at least one lavatory with a counter-top that is 34 inches...
-
Lavatory & Accessory Layouts
The trash receptacle is preferred to be near the door to allow people to pull the door open with a paper towel and drop it into the receptacle before exiting.
-
606.2 Clear Floor Space (Exception 3)
606.2 Clear Floor Space (Exception 3) This section requires clear floor space positioned for a forward approach and knee and toe clearance to be provided at lavatories and sinks....
-
Design Opportunity
) while keeping the counter/rim at 34" AFF maximum (606.3); and it may require more than 8" minimum knee clearance to provide the extended depth clear floor space required to reach the lavatory...
-
4.16.2 Clear Floor Space
Clear floor space for water closets not in stalls shall comply with Fig. 28. Clear floor space may be arranged to allow either a left-handed or right-handed approach.
-
4.16.2 CLEAR FLOOR SPACE
Clear floor space for water closets not in stalls shall comply with Fig. 28. Clear floor space may be arranged to allow either a left-handed or right-handed approach. Figure...
- Mansfield Lavatory 315
-
1134A.8, Item 6
Water supply and drain pipes under lavatories shall be insulated or otherwise covered to protect against contact. There shall be no sharp or abrasive surfaces under lavatories....
-
1134A.8, Item 6
Water supply and drain pipes under lavatories shall be insulated or otherwise covered to protect against contact. There shall be no sharp or abrasive surfaces under lavatories....