Clear floor spaces 30 inches (762 mm) by 48 inches (1219 mm), with centerlines aligned with the centerline of the work surface, appliance, sink or fixture, shall be provided in the...
Search Results "Kitchen"
-
11B-809.9.1 Clear floor space
- Pressalit Care Lift for Manually Height Adjustable Worktop
- Moen Delaney with MotionSense Spot Resist Stainless One-Handle High Arc Pulldown Kitchen Faucet
- Gaggenau Electric Cooktop CE 490
-
1133A.4.1, Item 3
3. The sides of adjacent cabinets and the back wall, which may become exposed to moisture or food handling when a countertop is lowered, shall be constructed of durable, nonabsorbent...
-
1133A.4.1, Item 3
3. The sides of adjacent cabinets and the back wall, which may become exposed to moisture or food handling when a countertop is lowered, shall be constructed of durable, nonabsorbent...
-
Example 2: Without Cooking Facilities
An employee break room without fixed or built-in range cooking facilities is not considered a kitchen or kitchenette; therefore, they are not subject to compliance with the requirements...
-
11B-804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door. The dishwasher door, in the open position, shall not obstruct the clear floor or ground space for the...
-
11B-804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door. The dishwasher door, in the open position, shall not obstruct the clear floor or ground space for the...
-
Dishwasher: ADA Standard Section 804.6.3
Clear floor or ground space shall be positioned adjacent to the dishwasher door. The dishwasher door, in the open position, shall not obstruct the clear floor or ground space for the...
-
7(1)(c)
(c) In U-shaped kitchens with sink or range or cooktop at the base of the "U", a 60-inch turning radius is provided to allow parallel approach, or base cabinets are removable at that location...
-
1133A.2.1, Item 1
U-shaped kitchens, designed with parallel approach at a range or cooktop located at the base of the U, shall have a minimum clear width of at least 60 inches (1524 mm)....
-
1133A.2.1, Item 1
U-shaped kitchens, designed with parallel approach at a range or cooktop located at the base of the U, shall have a minimum clear width of at least 60 inches (1524 mm)....
-
804.5 Storage
At least 50 percent of shelf space in storage facilities shall comply with 811. [ECTCR UFAS 4.34.6.10(1)]
-
11B-804.6.5.2 Bottom-hinged door ovens
Bottom-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to one side of the door.
-
804.6.5.2 Bottom-Hinged Door Ovens
Bottom-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to one side of the door.
-
804.6.5.1 Side-Hinged Door Ovens
Side-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to the latch side of the oven door.
-
11B-804.5 Storage
At least 50 percent of shelf space in storage facilities shall comply with Section 11B-811.
-
11B-804.6.5.1 Side-hinged door ovens
Side-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to the latch side of the oven door.
-
A4.34.6.1 CLEARANCE
The minimum clearances provide satisfactory maneuvering spaces for wheelchairs only if cabinets are removed at the sink.
-
11B-804.5 Storage
At least 50 percent of shelf space in storage facilities shall comply with Section 11B-811.
-
11B-804.6.5.2 Bottom-hinged door ovens
Bottom-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to one side of the door.
-
11B-804.6.5.1 Side-hinged door ovens
Side-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to the latch side of the oven door.
-
11B-804.5 Storage
At least 50 percent of shelf space in storage facilities shall comply with Section 11B-811.