Detectable warnings at curb ramps shall extend 36 inches (914 mm) in the direction of travel....
Search Results "Instrusion Detection"
-
11B-705.1.2.2 Curb ramps
-
Location Above Detectable Elements
Objects located above elements that are within can sweep can protrude 4” maximum from the leading edge of such elements provided that any required reach or clear floor space is not...
-
11B-247.1.2.4 Bus stops
Where detectable warnings are provided at bus stop boarding and alighting areas in compliance with Section 11B-810.2.3, detectable warnings shall comply with Sections 11B-705.1.1 and 11B...
-
11B-247.1.2.4 Bus stops
Where detectable warnings are provided at bus stop boarding and alighting areas in compliance with Section 11B-810.2.3, detectable warnings shall comply with Sections 11B-705.1.1 and 11B...
-
15) Curb ramps
15) Curb ramps ADAAG: Curb ramps must have detectable warnings (which must be raised truncated domes) (§4.7.7). UFAS: No requirement for detectable warnings on curb ramps....
-
11B-247.1.2.4 Bus stops
Where detectable warnings are provided at bus stop boarding and alighting areas in compliance with Section 11B-810.2.3, detectable warnings shall comply with Sections 11B-705.1.1 and 11B...
-
Section 406.8
Section 406.8 To maintain the status quo with respect to detectable warnings in pedestrian facilities, the Department is adding a provision (not found in the current version of the new...
-
R305.2.5 Pedestrian At-Grade Rail Crossings
At pedestrian at-grade rail crossings not located within a street or highway, detectable warning surfaces shall be placed on each side of the rail crossing....
-
11B-705.1.2.4 Bus stops
When detectable warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches...
-
11B-705.1.2.4 Bus stops
When detectable warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches...
-
11B-705.1.2.4 Bus stops
When detectable warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches...
-
Tactile Surface
The proposed rule included provisions that generally recognized alternative tactile surfaces equally detectable underfoot or other designs or technologies that provide equal or superior...
-
11B-705.1.2.3 Islands or cut-through medians
Detectable warnings at pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width of the pedestrian path or cut-through less 2 inches...
-
11B-705.1.2.3 Islands or cut-through medians
Detectable warnings at pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width of the pedestrian path or cut-through less 2 inches...
-
Detectable Warning Surfaces on Curb Ramps (Section-by-Section Analysis)
Detectable Warning Surfaces on Curb Ramps (Section-by-Section Analysis) When the Access Board issued the 1991 ADAAG, the guidelines contained a requirement for detectable warning surfaces...
-
R305.2.3 Blended Transitions
On blended transitions, detectable warning surfaces shall be placed at the back of curb....
-
11B-705.1.2.3 Islands or cut-through medians
Detectable warnings at pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width of the pedestrian path or cut-through less 2 inches...
-
406.8--Modification to 406 of Appendix D to 36 CFR Part 1191
406.8--Modification to 406 of Appendix D to 36 CFR Part 1191 A curb ramp shall have a detectable warning complying with 705....
-
4.29.7 Standardization
(Reserved).
-
4.7.7 WARNING TEXTURES
(Removed and reserved).
-
4.1.2(14)
(14) Tactile warnings shall be provided at hazardous conditions as specified in 4.29.3.
-
4.29.3* TACTILE WARNINGS ON DOORS TO HAZARDOUS AREAS
Doors that lead to areas that might prove dangerous to a blind person (for example, doors to loading platforms, boiler rooms, stages, and the like) shall be made identifiable to the...
-
4.29.2* TACTILE WARNINGS ON WALKING SURFACES
(Reserved).
-
4.29.7* STANDARDIZATION
Textured surfaces for tactile door warnings shall be standard within a building, facility, site, or complex of buildings.