[See subsections ...]
Search Results "Holding Cell"
Commonly Searched Documents
-
§ 35.152 Jails, detention and correctional facilities, and community correctional facilities.
-
Security
Security Accessible cells do not compromise the security of prison personnel....
-
Accessible Cells in Correctional Facilities
Many inmates in State and local correctional facilities have mobility disabilities and need to be housed in accessible cells....
-
Basic Features
Basic Features Inmates with disabilities - including those who use wheelchairs - need to be able to enter their cells and move around inside them, using the cells’ features without assistance...
-
Features of an Accessible Toilet
Drawing Notes:
-
Features of Accessible Lavatories and Mirrors
Drawing Notes:
-
Note
Note: Some features shown in this document may be inappropriate for cells where inmate suicide is a concern....
-
All Furniture
All furniture placed in accessible cells for the use of inmates with disabilities needs to be accessible....
-
2. Beds
2. Beds: Providing beds at an appropriate height, generally from 17 to 19 inches, facilitates transfers to and from wheelchairs. In some cases, an appropriately mounted grab bar can...
-
Features of Accessible Furniture
Drawing Notes:
-
2. Mirrors
2. Mirrors: If provided, mirrors need to be mounted with the bottom edge of the reflecting surface no higher than 40 inches above the floor.
-
Appropriate clear floor space
Appropriate clear floor space (shown by dashed lines) is needed adjacent to each cell feature (see page 1 diagrams on clear floor space)....
-
Room Layout and General Features
Drawing Notes:
-
4. Bed transfer space
4. Bed transfer space: A 30-inch by 48-inch clear floor space facilitates transfer from a wheelchair to the bed.
-
5. Bed with clear floor space
5. Bed with clear floor space for a side approach next to bed.
-
Turn Space
60-inch (1525mm) Diameter Space T-Shaped Space for 180 Degree Turns
-
3. Flush valve
3. Flush valve is located in reach range and is operable without tight grasping, twisting, or pinching.
-
Alterations to cells and program access. (Section-by-Section Analysis)
When addressing the issue of alterations of prison cells, the Department must consider the realities of many inaccessible state prisons and strained budgets against the title II program...
-
1. Side grab bar
1. Side grab bar: There is a grab bar on the adjacent side wall that is at least 40 inches long and from 33 to 36 inches above the floor.
-
5. Toilet centerline
5. Toilet centerline: The toilet bowl needs to be centered 18 inches from the side wall, so that inmates with disabilities can use the side grab bar.
-
3. Doors
3. Doors with 32 inches of clear opening width (when a sliding door is fully opened or a hinged door is open 90 degrees). Clear floor space is required in front of the door.
-
2. Rear grab bar
2. Rear grab bar: There is a grab bar behind the toilet that is at least 36 inches long and from 33 to 36 inches above the floor.
-
§ 35.151(k)(2) Alterations to detention and correctional facilities.
Altered cells with mobility features shall be provided in each classification level....
-
Communication. (Section-by-Section Analysis)
Several large disability advocacy organizations commented on the 2004 ADAAG section 232.2.2 requirement that at least 2 percent of the general holding cells and housing cells must be equipped...