Constructed elements on outdoor recreation access routes, passing spaces, and resting intervals shall comply with 307. Advisory 1016.9 Protruding Objects. Protruding objects on...
Search Results "Head End Wall"
-
1016.9 Protruding Objects
-
M305.5 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided....
-
M301.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided....
-
Problem Two (Protruding Objects)
Problem Two: A wall-mounted display case protrudes seven inches from the wall and the bottom of the case is 40 inches above the floor....
-
242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with 1009.2; transfer walls complying with 1009.4; or transfer systems complying with 1009.5....
-
F242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with 1009.2; transfer walls complying with 1009.4; or transfer systems complying with 1009.5....
-
Accessible Means of Entry to Spas
A pool lift, a transfer wall, or a transfer system will be permitted to provide the required accessible means of entry....
-
242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with 1009.2; transfer walls complying with 1009.4; or transfer systems complying with 1009.5....
-
11B-242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with Section 11B-1009.2; transfer walls complying with Section 11B-1009.4; or transfer systems complying with Section...
-
11B-242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with Section 11B-1009.2; transfer walls complying with Section 11B-1009.4; or transfer systems complying with Section...
-
11B-242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with Section 11B-1009.2; transfer walls complying with Section 11B-1009.4; or transfer systems complying with Section...
-
G. Women's Spa and Fitness Center Locker Room
(3) Defendants will install a transfer wall to permit access to the Women's Whirlpool located in the Quiet Room, pursuant to 2010 Standards §§ 242.4 and 1009.4....
-
M301.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided and shall comply with M305.5....
-
Seat Heights
Additionally, transfer walls at pool decks are between 16 and 19 inches above the ground (ADA-ABA Section 1009.4.2) [7]. ...
-
Problem Three (Protruding Objects)
Problem Three: The bottom of a set of stairs is open and voters who are blind or have vision loss can hit their head on the underside of the stairs....
-
1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with 1009....
-
1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with 1009....
-
11B-1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with Section 11B-1009....
-
1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with 1009....
-
11B-1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with Section 11B-1009....
-
11B-1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with Section 11B-1009....
-
M301.2.3.1 End Transfer Surface
End transfer surfaces shall be 28 inches (710 mm) wide minimum and 17 inches (430 mm) long minimum. ...
-
11B-404.2.7 Door and gate hardware
Access gates in barrier walls and fences protecting pools, spas, and hot tubs shall be permitted to have operable parts of the release of latch on self-latching devices at 54 inches (1372...
-
11B-404.2.7 Door and gate hardware