[F] SECTION 907 FIRE ALARM AND DETECTION SYSTEMS...
Search Results "Audible Alarm"
-
[F] SECTION 907
FIRE ALARM AND DETECTION SYSTEMS
-
In Your Guest Room:
If they are locked, report it right away. 1.2 Find the nearest fire alarm. Generally, it is located near the exit or stairwell door or elevators....
-
907.2.6.2.2 Manual fire alarm boxes
Manual fire alarm boxes are not required to be located in accordance with Section 907.3 where the fire alarm boxes are provided at staff-attended locations having direct supervision over...
-
CHAPTER 9 FIRE PROTECTION SYSTEMS
ETA Editor's Note Sections from California Building Code Chapter 9 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted. To...
-
CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS
ETA Editor's Note Sections from California Building Code Chapter 9 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted. To...
-
907.5.2.3 Visible alarms
In other than Group I-2 and I-2.1, visible alarm notification appliances are not required in alterations, except where an existing fire alarm system is upgraded or replaced, or a new fire...
-
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS ETA Editor's Note Sections from California Building Code Chapter 9 not adopted by Division of the State Architect - Access Compliance...
-
11B-806.3.1 Alarms
Where emergency warning systems are provided, fire alarms shall comply with Section 11B-702 and carbon monoxide alarms shall comply with Chapter 4....
-
907.5.2.3.4 Groups R-2.1, R-3.1 and R-4
hearing impaired, shall be provided with notification appliances for the hearing impaired installed in accordance with NFPA 72 and which shall [sic] activated upon initiation of the fire alarm...
-
907.5.2.3.4 Groups R-2.1, R-3.1 and R-4
hearing impaired, shall be provided with notification appliances for the hearing impaired installed in accordance with NFPA 72 and which shall [sic] activated upon initiation of the fire alarm...
-
11B-806.3.1 Alarms
Where emergency warning systems are provided, fire alarms shall comply with Section 11B-702 and carbon monoxide alarms shall comply with Chapter 4....
-
11B-806.3.1 Alarms
Where emergency warning systems are provided, fire alarms shall comply with Section 11B-702 and carbon monoxide alarms shall comply with Chapter 4....
-
Audible Hall Signals
Audible hall signals must indicate the direction of a responding car by the number of sounds (once for up and twice for down) or by verbal announcements (407.2.2.3)....
-
[F] 907.5.2.3 Visible alarms
[F] 907.5.2.3 Visible alarms. Visible alarm notification appliances shall be provided in accordance with Sections 907.5.2.3.1 through 907.5.2.3.5. Exceptions: 1. ...
-
1009.12 Alarms/emergency warning systems/two-way communication systems
Emergency warning systems provided as part of the fire alarm system and two-way communication systems required by Chapter 10 shall be designed and installed in accordance with NFPA 72 as...
-
[F] 907.5.2.3 Visible alarms
Exceptions: In other than Group I-2 and I-2.1, visible alarm notification appliances are not required in alterations, except where an existing fire alarm system is upgraded or replaced...
-
[F] 907.5.2 Alarm notification appliances
...
-
4.28.1 GENERAL
Alarm systems required to be accessible by 4.1 shall comply with 4.28....
-
[F] 907.5.2.3.2 Groups R-1 and R-2.1
Habitable spaces in dwelling units and sleeping units in Group R-1 and R-2.1 occupancies in accordance with Table 907.5.2.3.2 shall be provided with visible alarm notification....
-
4.28.3(8)
(8) No place in common corridors or hallways in which visual alarm signalling appliances are required shall be more than 50 ft (15 m) from the signal....
-
[F] 907.5.2.3.3 Groups R-1 and R-2.1
Group R-1 and R-2.1 dwelling units or sleeping units in accordance with Table 907.5.2.3.3 shall be provided with a visible alarm notification appliance, activated by both the in-room smoke...
-
[F] 907.5.2.3.2 Groups R-1 and R-2.1
Group R-1 and R-2.1 dwelling units or sleeping units in accordance with Table 907.5.2.3.2 shall be provided with a visible alarm notification appliance, activated by both the in-room smoke...
-
4.28.1 General
Alarm systems required to be accessible by 4.1 shall comply with 4.28....
-
[F] 907.4.2 Manual fire alarm boxes
...