(c) In U-shaped kitchens with sink or range or cooktop at the base of the "U", a 60-inch turning radius is provided to allow parallel approach, or base cabinets are removable at that location...
Search Results "Removable Base Cabinet"
-
7(1)(c)
-
7(2)(a)
(a) Bathrooms that have reinforced walls for grab bars (see Requirement 6) would meet section 100.205(c)(3)(iv) if: Note: Cabinets under lavatories are acceptable provided the bathroom...
-
1133A.1 General
Kitchens shall be on an accessible route and shall comply with this section. (See Figure 11A-10A.)
-
1133A.1 General
) (1) 30" minimum countertop space for sink installation with removable base cabinet and finish flooring beneath the sink; 30" x 48" minimum clear floor space to allow parallel...
-
1133A.3 Removable base cabinets
Base cabinets (including toeboard and shelving) directly under kitchen sinks and work surfaces shall be removable without the use of specialized tools or specialized knowledge in order to...
-
1133A.3 Removable base cabinets
Base cabinets (including toeboard and shelving) directly under kitchen sinks and work surfaces shall be removable without the use of specialized tools or specialized knowledge in order to...
-
1133A.4.1, Item 2
Base cabinets directly under sinks and work surfaces shall be removable as required in Section 1133A.3....
-
1133A.7, Item 1
The knee and toe space shall be clear and unobstructed, or removable base cabinets in compliance with Section 1133A.3 shall be provided....
-
1134A.8, Item 4.3
Doors to the cabinet beneath the lavatory shall be removable or openable to provide the required unobstructed knee and toe space....
-
11B-233.3.1.2.6 Public housing facility site impracticality
ETA Editor's Note This section of the 2019 California Building Code was amended by the Division of the State Architect. The requirements in this section were previously found in...
-
11B-233.3.1.2.6 Public housing facility site impracticality
The site impracticality tests in this section may be used to determine the number of required residential dwelling units with adaptable features in buildings without an elevator,...
-
11B-233.3.1.2.6 Public housing facility site impracticality
Kitchen sink removable cabinets complying with Section 11B-606.2, Exception 3. ...
-
11B-233.3.1.2.6 Public housing facility site impracticality
The site impracticality tests in this section may be used to determine the number of required residential dwelling units with adaptable features in buildings without an elevator,...
-
11B-233.3.1.2.6.5 Additional requirements.
Removable base cabinets complying with Section 11B-809.9.3. Advisory 11B-233.3.1.2.6. Site Impracticality....
-
11B-233.3.1.2.6.5 Additional requirements.
Removable base cabinets complying with Section 11B-809.9.3....
-
11B-233.3.1.2.6.5 Additional requirements.
Removable base cabinets complying with Section 11B-809.9.3....
-
11B-809.9.3 Removable base cabinets
Exception: Removable base cabinets shall be permitted under sinks and work surfaces provided that all of the following conditions are met: a) base cabinets can be removed without the...
-
11B-809.9.3 Removable base cabinets
Exception: Removable base cabinets shall be permitted under sinks and work surfaces provided that all of the following conditions are met: a) base cabinets can be removed without the...
-
11B-809.9.3 Removable base cabinets
Exception: Removable base cabinets shall be permitted under sinks and work surfaces provided that all of the following conditions are met: a) base cabinets can be removed without the...
-
11B-809.10.8.3 Cabinets
Cabinets shall be removable without the use of specialized knowledge and/or tools. The finished floor shall extend to the wall under the lavatory....
-
11B-809.10.8.3 Cabinets
Cabinets shall be removable without the use of specialized knowledge and/or tools. The finished floor shall extend to the wall under the lavatory....
-
11B-809.10.8.3 Cabinets
Cabinets shall be removable without the use of specialized knowledge and/or tools. The finished floor shall extend to the wall under the lavatory....
-
30.1 Q. Would it be acceptable to use removable base cabinets beneath a wall-hung lavatory where a parallel approach is not possible?
The space under and around the cabinet should be finished prior to installation. For example, the tile or other floor finish must extend under the removable base cabinet....
-
FIGURE 11A-10A KITCHEN SPECIFICATIONS
(1) 30" minimum countertop space for sink installation with removable base cabinet and finish flooring beneath the sink; 30" x 48" minimum clear floor space to allow parallel or forward...