Fire rings, grills, fireplaces, and wood stoves shall comply with 1011.5. Advisory 1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves. ...
Search Results "Wood Stove"
Commonly Searched Documents
-
1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves
-
1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves
Fire rings, grills, fireplaces, and wood stoves shall comply with 1011.5. Advisory 1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves....
-
1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves
This section requires fire building surfaces to be 9 inches minimum above the ground, and cooking surfaces to be 15 inches minimum and 34 inches maximum above the ground. Where fire...
-
4.2 Fire Rings, Grills, Fireplaces, and Wood Stoves
[See subsections ...]
-
4.2.3 Operable Parts
Exception: Fire rings, grills, fireplaces, and wood stoves shall not be required to comply with ABAAS section 309.4 until models that comply are readily available from more than one source...
-
1011.5.3 Raised Edges or Walls
Where fire rings, grills, or fireplaces are constructed with raised edges or walls, the depth of the raised edge or wall shall be 10 inches (255 mm) maximum.
-
1011.5.3 Raised Edges or Walls
Where fire rings, grills, or fireplaces are constructed with raised edges or walls, the depth of the raised edge or wall shall be 10 inches (255 mm) maximum.
-
Fire Rings, Grills, Fireplaces, and Wood Stoves
An outdoor recreation access route must connect fire rings, grills, fireplaces or wood stoves that are provided in recreation sites to the other major constructed features at the recreation...
-
1011.5.2 Cooking Surfaces
Where provided, cooking surfaces shall be 15 inches (380 mm) minimum and 34 inches (865 mm) maximum above the ground.
-
4.2.1 General
Where fire rings, grills, fireplaces, or woodstoves are provided, each shall comply with section 4.2. Exception. In alterations, where a condition for exception in section 1.1...
-
4.2.2 Cooking Surface Height
The cooking surface shall be at least 15 inches (380 mm) and no more than 34 inches (865 mm) above the floor or ground surface.
-
1011.5.2 Cooking Surfaces
Where provided, cooking surfaces shall be 15 inches (380 mm) minimum and 34 inches (865 mm) maximum above the ground.
-
1011.5.1 Fire Building Surfaces
Fire building surfaces shall be 9 inches (230 mm) minimum above the ground.
-
1011.5.1 Fire Building Surfaces
Fire building surfaces shall be 9 inches (230 mm) minimum above the ground.
-
Fire Rings, Grills, Fireplaces, and Woodstoves [1011.2, 1011.3, and 1011.5]
The operable parts of fire rings, grills, fireplaces, and wood stoves must be between 15 and 48 inches above the ground (figure 22)....
-
4.2.8 Slope
The slope of the clear floor or ground space required by section 4.2.6 shall not exceed 1:48 (2 percent) in any direction. Exception. When the surface is not paved or is not...
-
4.2.6 Clear Floor or Ground Space
At least 48 inches (1220 mm) by 48 inches (1220 mm) of clear floor or ground space shall be provided on all usable sides of fire rings, grills, fireplaces or woodstoves. This space...
-
Camp Living Area
Camp Living Area. The area in a camping unit that contains constructed features, such as picnic tables, grills, fire rings, utilities, and other related elements, and may be...
-
Improved Engineered Wood Fiber (EWF) Surfaces for Accessible Playgrounds Field Performance Testing: Final Report II
Improved Engineered Wood Fiber (EWF) Surfaces for Accessible Playgrounds Field Performance Testing: Final Report II Field Performance Testing March, 2002 – January, 2003 USDA...
-
Definition [F106.5]
Outdoor constructed features are picnic tables, fire rings, grills, fireplaces, wood stoves, trash and recycling receptacles, water hydrants, utility and sewage hookups, outdoor rinsing...
-
4.2.7 Surface
The surface of the clear floor or ground space shall be firm and stable. The type of surface should be appropriate to the setting and level of development.
-
Engineered Wood Fiber
Engineered Wood Fiber There were six sites surfaced entirely with engineered wood fiber (EWF). ...
-
1011.3 Operable Parts
Fire rings, grills, fireplaces, wood stoves, water hydrants, and water utility hookups shall comply with 309.4 to the extent practicable. 2. ...
-
1011.3 Operable Parts
Fire rings, grills, fireplaces, wood stoves, water hydrants, and water utility hookups shall comply with 309.4 to the extent practicable. 2....