Section 505.10 covers the current ADA Standards for handrail extensions.
Search Results "Stair Handrail"
Commonly Searched Documents
-
Handrail Extensions: ADA Standard Section 505.10
-
Bottom Extension at Stairs: ADA Standard Section 505.10.3
Section 505.10.3 covers the current ADA Standards for the handrail extensions at the bottom of the stairs.
-
Top Extension at Stairs: ADA Standard Section 505.10.2
Section 505.10.2 covers the current ADA Standards for the handrail extensions at the top of the stairs.
-
Handrails: ADA Standard Section 1009.6.2
The width between handrails shall be 20 inches (510 mm) minimum and 24 inches (610 mm) maximum. Handrail extensions required by 505.10.3 shall not be required on pool stairs....
-
11B-1009.6.2 Handrails
The width between handrails shall be 20 inches (508 mm) minimum and 24 inches (610 mm) maximum....
-
Handrails: ADA Standard Section 504.6
Section 504.6 covers the current ADA Standards for handrails at stairways.
-
11B-504.6 Handrails
Stairs shall have handrails complying with Section 11B-505....
-
11B-505.10.3 Bottom extension at stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance equal to one tread depth beyond the last riser nosing....
-
11B-505.10.2 Top extension at stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
Fittings: ADA Standard Section 505.9
Section 505.9 covers the current ADA Standards for handrail fittings.
-
11B-505.2.1 Orientation
The orientation of at least one handrail shall be in the direction of the stair run, perpendicular to the direction of the stair nosing, and shall not reduce the minimum required width of...
-
Surfaces: ADA Standard Section 505.8
Section 505.8 covers the current ADA Standards for handrail gripping surfaces and also any adjacent surfaces to them.
-
11B-505.10 Handrail extensions
Handrail gripping surfaces shall extend beyond and in the same direction of stair flights and ramp runs in accordance with Section 11B-505.10....
- PromenAid Handrail System
-
General: ADA Standard Section 505.1
Section 505.1 of the ADA Standards covers information in the current ADA Standards for handrails.
-
11B-505.1 General
Handrails provided along walking surfaces complying with Section 11B-403, required at ramps complying with Section 11B-405, and required at stairs complying with Section 11B-504 shall comply...
- Madden Manufacturing Round Handrail (ADA Compliant)
- Simplified Building Concepts ADA Handrail
-
11B-505.9 Fittings
Handrails shall not rotate within their fittings....
-
1011.11 Handrails
... [DSA-AC] For applications listed in Section 1.9.1 regulated by the Division of the State Architect-Access Compliance, see Chapter 11B, Sections 11B-504.6 and 11B-505.
-
Cross Section: ADA Standard Section 505.7
Section 505.7 covers the current ADA Standards for the cross section of handrail gripping surfaces.
-
Handrails
Handrails Pool stairs must have handrails with a minimum width between the rails of 20 inches and a maximum of 24 inches....
-
Continuity: ADA Standard Section 505.3
Section 505.3 covers the current ADA Standards for the continuity of handrails.
-
11B-505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....