In altered facilities, stairs serving levels that are connected by an accessible route do not have to comply, but must be equipped with complying handrails....
Search Results "Stair Handrail"
-
210 Stairways
-
210.1 General
In alterations, stairs between levels that are connected by an accessible route shall not be required to comply with 504, except that handrails complying with 505 shall be provided when...
-
505.1 General
Handrails provided along walking surfaces complying with 403, required at ramps complying with 405, and required at stairs complying with 504 shall comply with 505....
-
505.2 Where Required
Handrails shall be provided on both sides of stairs and ramps....
-
505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
505.6 Gripping Surface
Handrail gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides....
-
505.7 Cross Section
Handrail gripping surfaces shall have a cross section complying with 505.7.1 or 505.7.2....
-
505.7.1 Circular Cross Section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1 1/4 inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
505.7.2 Non-Circular Cross Sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6 1/4 inches (160 mm) maximum, and a cross-section dimension...
-
505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
505.9 Fittings
Handrails shall not rotate within their fittings....
-
505.10 Handrail Extensions
Handrail gripping surfaces shall extend beyond and in the same direction of stair flights and ramp runs in accordance with 505.10. EXCEPTIONS: 1....
-
505.10.2 Top Extension at Stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
505.10.3 Bottom Extension at Stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
-
Attachment H: Modifications to Altered Facilities
Attachment H: Modifications to Altered Facilities
-
11B-505.2.1 Orientation
Adds requirement that at least one handrail must be in direction of travel, perpendicular to the stair nosing....
-
Verify Framing
bathtub/shower rooms. 11B-610 Width and depth of shower stalls. 11B-608.2 Drinking fountain alcoves/wing walls. 11B-602.9 Tread dimensions on stairs...
-
Verify Framing
bathtub/shower rooms. 11B-610 Width and depth of shower stalls. 11B-608.2 Drinking fountain alcoves/wing walls. 11B-602.9 Tread dimensions on stairs...
-
Alterations to stairs (Section-by-Section Analysis)
However, exception 2 of section 210.1 of the 2010 Standards provides that in alterations, stairs between levels connected by an accessible route need not be accessible, except that handrails...
-
Stairs
Full handrail extensions at stairs are not required where they would project hazardously into circulation paths (ยง505.10, Ex. 3)....
-
210.1 General
In alterations, stairs between levels that are connected by an accessible route shall not be required to comply with 504, except that handrails complying with 505 shall be provided when...
-
Alterations to stairs. (Section-by-Section Analysis)
However, exception 2 of section 210.1 of the 2010 Standards provides that in alterations, stairs between levels connected by an accessible route need not be accessible, except that handrails...
-
F210.1 General
In alterations, stairs between levels that are connected by an accessible route shall not be required to comply with 504, except that handrails complying with 505 shall be provided when...