5.7.1.1 Lift Compatibility Clearance in Base for Stretchers. The base of the equipment must provide a clearance of 39 inches wide minimum....
Search Results "Lift Compatibility"
Commonly Searched Documents
-
5.7.1.1 Lift Compatibility Clearance in Base for Stretchers
-
M301.4 Lift Compatibility
M301.4 Lift Compatibility M01.4.1 Clearance in Base Proposed requirement: The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm)...
-
5.7.1.1 Lift Compatibility Clearance in Base for Stretchers (M301)
5.7.1.1 Lift Compatibility Clearance in Base for Stretchers (M301) The Committee recommends the equipment base provide a clearance of 39 inches wide minimum....
-
M302.4 Lift Compatibility
Diagnostic equipment shall be usable with portable patient lifts and, when in use with such lifts, shall comply with M302.4.1 or M302.4.2. ...
-
3. Lift Compatibility Exception
The proposed rule specified base clearance requirements to ensure lift compatibility (M301.4 and M302.4, respectively)....
-
M301.4 Lift Compatibility
M301.4 Lift Compatibility Subcommittee Recommendation: (Also agreed to by the full committee.)...
-
Receiver Hearing-Aid Compatibility: ADA Standard Section 706.3
Receivers required to be hearing-aid compatible shall interface with telecoils in hearing aids through the provision of neckloops....
-
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment....
-
M302.4 Lift Compatibility (Section-by-Section Analysis)
This requirement is identical to the lift compatibility requirement for diagnostic equipment used by patients in the supine, prone, or side-lying position, and is discussed in the Section-by...
-
M301.4 Lift Compatibility
Diagnostic equipment shall be usable with portable patient lifts and, when in use with such lifts, shall comply with M301.4.1 or M301.4.2....
-
M302.4 Lift Compatibility
Diagnostic equipment shall be usable with a patient lift and shall comply with M302.4.1 or M302.4.2....
-
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment (M301)
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment (M301) The Committee recommends the use of alternative means of access by an overhead lift in place of clearances in...
-
Pool Lift Location: ADA Standard Section 1009.2.1
Pool lifts shall be located where the water level does not exceed 48 inches (1220 mm). EXCEPTIONS: 1....
-
5.7 Lift Compatibility
5.7 Lift Compatibility....
-
M301.4 Lift Compatibility
Diagnostic equipment shall be usable with a patient lift and shall comply with M301.4.1 or M301.4.2....
-
5.7 Lift Compatibility Recommendations
5.7 Lift Compatibility Recommendations...
-
Compatible
Compatible: The FCC requires that, where accessibility is not readily achievable, a product or service must be made compatible with peripheral devices or specialized equipment, if compatibility...
-
M301.4 Lift Compatibility (Section-by-Section Analysis)
Additionally, question 27 in the MDE NPRM preamble requested input on whether the final rule should provide an exception from the lift compatibility requirements where the diagnostic equipment...
-
Lifting Capacity: ADA Standard Section 1009.2.9
Single person pool lifts shall have a weight capacity of 300 pounds. (136 kg) minimum and be capable of sustaining a static load of at least one and a half times the rated load....
-
Compatible (Section-by-Section Analysis)
Compatible (Section-by-Section Analysis) Subpart D contains the minimum requirements for compatibility with existing peripheral devices or specialized customer premises equipment commonly...
-
11B-1009.2.9 Lifting capacity
Single person pool lifts shall have a weight capacity of 300 pounds (136 kg) minimum and be capable of sustaining a static load of at least one and a half times the rated load....
-
Lift Compatibility (M301.4 and M302.4)
Portable floor lifts have legs with wheels that need to fit under or around the base of the diagnostic equipment....
-
Compatible
Telecommunications equipment or customer premises equipment which comply with the requirements of Subpart D.
-
Figure M2: M301.4 Lift Compatibility
(at Diagnostic Equipment for Use by a Patient in a Supine, Prone, or Side-Lying Position)