§ 36.304(b)(6)
-
Attachment I: Program Access in Existing Facilities
Attachment I: Program Access in Existing Facilities
-
Priority 2: Access to Goods & Services
Word Fillable Form (2.5MB) Word Non-Fillable Form (2.4MB) PDF Non-Fillable Form (1.4MB)
-
Verify Electrical
Measure to top or bottom of boxes 11B-308.1.2 Alarm/detector systems. 11B-702 Height of HVAC controls....
-
Verify Electrical
Measure to top or bottom of boxes 11B-308.1.2 Alarm/detector systems. 11B-702 Height of HVAC controls....
-
Sec.36.304(b)(6)
(6) Adding raised markings on elevator control buttons;...
-
Car Controls
...are the highest floor control buttons in the elevator(s) mounted within 54" of the floor, with associated raised letters and Braille characters?...
-
e-iv
Are the highest floor control buttons mounted no more than 54 inches above the floor for a side reach or 48 inches for forward reach? [ADA Standards § 4.10.12 (3)] Yes No...
-
e-v
Are raised letters and Braille characters used to identify each floor button and each control? [ADA Standards § 4.10.12] Yes No...
-
Elevator Car Controls
Comments recommended that the height of elevator car controls be harmonized with the ANSI A117.1 standard....
-
407.4.6 Elevator Car Controls
Where provided, elevator car controls shall comply with 407.4.6 and 309.4....
-
407.4.6.1 Location
Controls shall be located within one of the reach ranges specified in 308. EXCEPTIONS: 1....
-
407.4.6.2 Buttons
Car control buttons with floor designations shall comply with 407.4.6.2 and shall be raised or flush. EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
407.4.6.2.1 Size
Buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension.
-
407.4.6.2.2 Arrangement
Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right.
-
407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (890 mm) minimum above the finish floor....
-
407.4.6.4.2 Location
Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel....
-
407.4.7 Designations and Indicators of Car Controls
Designations and indicators of car controls shall comply with 407.4.7....
-
407.4.7.1 Buttons
Car control buttons shall comply with 407.4.7.1....
-
407.4.7.1.1 Type
Control buttons shall be identified by tactile characters complying with 703.2....
-
407.4.7.1.2 Location
Raised character and braille designations shall be placed immediately to the left of the control button to which the designations apply....
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....
-
407.4.7.1.4 Visible Indicators
The visible indication shall extinguish when the car arrives at the designated floor....
-
407.4.7.2 Keypads
Keypads shall be identified by characters complying with 703.5 and shall be centered on the corresponding keypad button. The number five key shall have a single raised dot. The dot...