Section 403.5.2 covers the current ADA Standards for the clear width at a turn on walking surfaces that are part of an accessible route.
Search Results "Clear Width at Turn"
Commonly Searched Documents
-
Clear Width at Turn: ADA Standard Section 403.5.2
-
11B-403.5.2 Clear width at turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1219 mm) wide, clear width shall be 42 inches (1067 mm) minimum approaching the turn, 48...
-
Clear Width: ADA Standard Section 403.5.1
Section 403.5.1 covers the current ADA Standards for the clear width of walking surfaces that are part of an accessible route.
- Figure 403.5.2 Clear Width at Turn – Drawing from the U.S. Access Board
-
Required Clear Width: ADA Standard Section 307.5
Section 307.5 covers the current ADA Standards for protruding objects not reducing the required clear width of an accessible route.
-
Clear Width: ADA Standard Section 404.3.1
Section 404.3.1 covers the current ADA Standards for clear width at automatic and power-assisted doors and gates.
-
403.5.2 Clear Width at Turn
403.5.2 Clear Width at Turn....
-
403.5.2 Clear Width at Turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1220 mm) wide, clear width shall be 42 inches (1065 mm) minimum approaching the turn, 48...
-
403.5.2 Clear Width at Turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1220 mm) wide, clear width shall be 42 inches (1065 mm) minimum approaching the turn, 48...
-
Clear Width: ADA Standard Section 1008.2.4
Accessible routes connecting play components shall provide a clear width complying with 1008.2.4....
-
11B-403.5.2 Clear width at turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1219 mm) wide, clear width shall be 42 inches (1067 mm) minimum approaching the turn,...
-
11B-403.5.2 Clear width at turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1219 mm) wide, clear width shall be 42 inches (1067 mm) minimum approaching the turn, 48...
-
11B-403.5.2 Clear width at turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1219 mm) wide, clear width shall be 42 inches (1067 mm) minimum approaching the turn, 48...
-
Clear Width: ADA Standard Section 404.2.3
Section 404.2.3 covers the current ADA Standards for clear width at manual doors, doorways and manual gates that are part of an accessible route.
-
Clear Width: ADA Standard Section 1006.3.1
The clear width of golf car passages shall be 48 inches (1220 mm) minimum....
-
Ground Level: ADA Standard Section 1008.2.4.1
At ground level, the clear width of accessible routes shall be 60 inches (1525 mm) minimum. EXCEPTIONS: 1....
-
11B-1008.2.4.1 Ground level
At ground level, the clear width of accessible routes shall be 60 inches (1524 mm) minimum....
-
Accessible Pathway & Corridor: Minimum Clear Width Required for 180-degree Turn
perform a 90-degree turn....
-
Accessible Pathway & Corridor: Minimum Clear Width Required for 180-degree Turn Around Barrier
The bold dashed line in the table and figure indicates the current ADA-ABA requirements, which vary based on the passage width and space available at the base of the turn....
-
180 Turns Around Obstructions
Additional clearance is required at 180 degree turns around an element that is less than 48” wide....
-
Clear Width: ADA Standard Section 405.5
Section 405.5 covers the current ADA Standards for the clear width requirements of ramps.
-
4.3.5.2 180-degree turn
Figure 4-5: Accommodation model depicting the minimum clear width required by users of manual wheelchairs, powered chairs and scooters to complete a 180-degree turn....
-
4.3.5.3 180-degree turn around an obstacle
This would increase the width slightly but reduce the depth of the turning area significantly....
-
Turning Space [§304]
Turning Space [§304] Turning space is required in these accessible rooms and spaces: toilet and bathing facilities dressing, fitting, and locker rooms transient...