Section 407.2.1 covers the current ADA Standards for elevator call controls.
Search Results "Call button"
Commonly Searched Documents
-
Call Controls: ADA Standard Section 407.2.1
-
Call Buttons: ADA Standard Section 409.2
Section 409.2 covers the current ADA Standards for call buttons in private residence elevators.
-
Call Buttons: ADA Standard Section 408.2.1
Section 408.2.1 covers the current ADA Standards for limited-use/limited-application elevator call buttons.
-
11B-407.2.1 Call controls
Where elevator call buttons or keypads are provided, they shall comply with Sections 11B-407.2.1 and 11B-309.4. [2010 ADA Standards] 407.2.1 Call Controls....
-
11B-409.2 Call buttons
Call buttons shall be ¾ inch (19.1 mm) minimum in the smallest dimension and shall comply with Section 11B-309....
-
11B-411.2.1.5 Button requirements
Keypad buttons, the accessibility function button, and additional hall call console buttons shall comply with Section 11B-411.2.1.5....
-
Size: ADA Standard Section 407.2.1.2
Section 407.2.1.2 covers the current ADA Standards for the size of the elevator call controls.
-
11B-407.2.1.2 Size and shape
Call buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
Height: ADA Standard Section 407.2.1.1
Section 407.2.1.1 covers the current ADA Standards for the height of the elevator call controls.
-
11B-408.2.1 Call buttons
Elevator call buttons and keypads shall comply with Section 11B-407.2.1....
-
11B-411.2.1.4.1 Hall call console additional buttons
Hall call console buttons provided in addition to the accessibility function button and keypad buttons shall comply with Section 11B-411.2.1.4.1....
-
11B-411.2.1.4.1.2 Identification
Buttons shall be identified by raised characters and symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
11B-411.2.1.5.2 Color
Characters and symbols on buttons, where provided, shall be white on a black background....
-
11B-407.2.1.6 Keypads
ETA Editor's Note Lacking certain Exceptions allowed by 2010 ADA Standards, and imposing additional requirements regarding call buttons, the preceding CBC requirements pertaining to...
-
Location: ADA Standard Section 407.2.1.4
Section 407.2.1.4 covers the current ADA Standards for the location of elevator call controls.
-
Hall Call Buttons [4.10.3]
These specifications apply to all hall call buttons provided, including those that serve cars that operate independently from others in the same bank or lobby....
-
11B-411.2.1.3.2 Touch screen call console arrangement
Where touch screen call consoles are provided, the touch screen shall be located directly above the accessibility function button....
-
11B-407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception: Reserved....
-
11B-411.2.1.3.1 Keypad call console arrangement
Where keypad call consoles are provided, the display screen shall be located directly above the keypad....
-
Signals: ADA Standard Section 407.2.1.5
Section 407.2.1.5 covers the current ADA Standards for elevator call control signals.
-
Clear Floor or Ground Space: ADA Standard Section 407.2.1.3
Section 407.2.1.3 covers the current ADA Standards for the clear floor or ground space at elevator call controls.
-
11B-411.2.1.4.1.1 Arrangement
Buttons shall be arranged in columns to the right of the keypad with a minimum horizontal spacing of 1.5 times the horizontal spacing between the numeric keys and with the same vertical...
-
11B-407.2.1 Call controls
Where elevator call buttons or keypads are provided, they shall comply with Sections 11B-407.2.1 and 11B-309.4 _|Operation|_. [2010 ADAS] 407.2.1 Call Controls. ...