Figure 604.8.1.4 Wheelchair Accessible Toilet Compartment Toe Clearance...
Search Results "Patient Seated in Wheelchair"
Commonly Searched Documents
-
604.8.1.4 Toe Clearance
-
11B-604 Water closets and toilet compartments
Patient toilet rooms with bedpan flushing devices are an allowance, not a requirement....
-
608.3.3 Alternate Roll-In Type Shower Compartments
Grab bars shall not be provided above the seat. Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls....
-
607.2 Clearance
Where a permanent seat is provided at the head end of the bathtub, the clearance shall extend 12 inches (305 mm) minimum beyond the wall at the head end of the bathtub....
-
11B-608.3.3 Alternate roll-in type shower compartments
Grab bars shall not be provided above the seat. Grab bars shall be installed 6 inches (152 mm) maximum from adjacent walls....
-
11B-608.3.3 Alternate roll-in type shower compartments
Grab bars shall not be provided above the seat. Grab bars shall be installed 6 inches (152 mm) maximum from adjacent walls....
-
604.8.1.4 Toe Clearance
[ECTCR UFAS 4.17.4] Figure 604.8.1.4 Wheelchair Accessible Toilet Compartment Toe Clearance...
-
604.8.1.4 Toe Clearance
Figure 604.8.1.4 Wheelchair Accessible Toilet Compartment Toe Clearance...
-
11B-223 Medical care and long-term care facilities
In licensed medical care facilities and licensed long-term care facilities where the period of stay exceeds twenty-four hours, patient bedrooms or resident sleeping rooms shall be provided...
-
Clear Floor Space
Clear Floor Space The load and unload areas adjacent to ride seats designed for transfer must have a clear space of 30 by 48 inches minimum....
-
§ 38.107(a)
(a) If a restroom is provided for the general public, it shall be designed so as to allow a person using a wheelchair or mobility aid to enter and use such restroom as specified in paragraphs...
-
608.3.3 Alternate Roll-In Type Shower Compartments
Grab bars shall not be provided above the seat. Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls....
-
607.2 Clearance
Where a permanent seat is provided at the head end of the bathtub, the clearance shall extend 12 inches (305 mm) minimum beyond the wall at the head end of the bathtub....
-
604.8 Toilet Compartments
Wheelchair accessible toilet compartments shall meet the requirements of 604.8.1 and 604.8.3. Compartments containing more than one plumbing fixture shall comply with 603....
-
604.8 Toilet Compartments
Wheelchair accessible toilet compartments shall meet the requirements of 604.8.1 and 604.8.3. Compartments containing more than one plumbing fixture shall comply with 603....
-
607.2 Clearance
Where a permanent seat is provided at the head end of the bathtub, the clearance shall extend 12 inches (305 mm) minimum beyond the wall at the head end of the bathtub....
-
Guest Bathrooms
The depth of a removable in-tub seat shall be 15 inches (380 mm) minimum and 16 inches (405 mm) maximum. The seat shall be capable of secure placement....
-
604.8 Toilet Compartments
Wheelchair accessible toilet compartments shall meet the requirements of 604.8.1 and 604.8.3. Compartments containing more than one plumbing fixture shall comply with 603....
-
Summary
This project developed drawings for gates that meet the accessibility requirements for wheelchairs, horses, or both, but restrict motorized vehicle access....
-
F206.2.4 Spaces and Elements
In assembly areas with fixed seating required to comply with F221, an accessible route shall not be required to serve fixed seating where wheelchair spaces required to be on an accessible...
-
206.2.4 Spaces and Elements
In assembly areas with fixed seating required to comply with 221, an accessible route shall not be required to serve fixed seating where wheelchair spaces required to be on an accessible...
-
11B-604.8 Toilet compartments
Wheelchair accessible toilet compartments shall meet the requirements of Sections 11B-604.8.1 and 11B-604.8.3 _|Coat Hooks and Shelves|_....
-
§ 35.151(e)(2)
(2) Facilities with more than 50 beds covered by this section that provide common use bathing facilities shall provide at least one roll-in shower with a seat that complies with the relevant...
-
The Impact of Transfer Setup on the Performance of Independent Transfers: Phase I Final Report
The Impact of Transfer Setup on the Performance of Independent Transfers: Final Report REPORT PREPARED FOR: U.S. ACCESS BOARD, WASHINGTON, DC Authors: Alicia Koontz, PhD,...