Signs shall be provided in accordance with 216 and shall comply with 703. EXCEPTIONS: 1. Building directories, menus, seat and row designations in assembly areas, occupant...
Search Results "Ground Floor Exit"
-
216.1 General
-
703.1 General
703.1 General. Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
1134A.7, Item 1
Floor space and location. The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width....
-
1133A.7, Item 3
A clear floor space shall not extend into the knee and toe space more than 19 inches (483 mm)....
-
1133A.7, Item 3
A clear floor space shall not extend into the knee and toe space more than 19 inches (483 mm)....
-
2. a. iv. Path-of-Travel (wheelchair) space allowances
If a 180° turn is needed to exit an area, then a 60” diameter turning space or a 36” wide "T" is needed (see Figure 11)....
-
4.35.4 Bench
The bench shall be mounted 17 in to 19 in (430 mm to 485 mm) above the finish floor....
-
1134A.7, Item 1
Floor space and location. The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width. ...
-
Section H: Lifts
(§410.1) H3 Is there 30" by 48" of clear floor space within the lift?...
-
§ 38.125(d)(2) Wheelchair or mobility aid spaces
Spaces for persons who wish to remain in their wheelchairs or mobility aids shall have a minimum clear floor space 48 inches by 30 inches....
- Bosch Power Tools - GPL-3 3 Point Laser
-
M304.2 Standing Surface (Section-by-Section Analysis)
In preparing the final rule, the Board has determined that as previously drafted this provision unintentionally placed requirements on the facility floor, as opposed to restricting the requirements...
-
F216.2 Designations
Examples include interior signs labeling restrooms, room and floor numbers or letters, and room names....
-
216.2 Designations
Examples include interior signs labeling restrooms, room and floor numbers or letters, and room names....
-
216.2 Designations
Examples include interior signs labeling restrooms, room and floor numbers or letters, and room names....
-
11B-809.10.4 Sufficient maneuvering space
Doors shall be permitted to encroach into the clear floor space or clearance for fixtures where clear maneuvering space is provided outside the arc of the door swing....
-
11B-809.10.4 Sufficient maneuvering space
Doors shall be permitted to encroach into the clear floor space or clearance for fixtures where clear maneuvering space is provided outside the arc of the door swing....
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—in-swinging doors (Req. # 32)
those with in-swinging doors tend to be larger (in terms of square footage) in order to accommodate clearance for the in-swinging door and, thus, are already likely to have adequate clear floor...
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—in-swinging doors (Req. # 32)
those with in-swinging doors tend to be larger terms of square footage) in order to accommodate clearance for the in-swinging door and, thus, are already likely to have adequate clear floor...
- Access Board: Tactile Sign Location
- Access Board: Tactile Sign Height
-
§ 38.95(c)(5) Slope
If the height of the vehicle floor, under 50% passenger load, from which the ramp is deployed is 3 inches or less above the station platform a maximum slope of 1:4 is permitted; if the height...
- Access Board: Clear Floor Space Position
-
Changes in Level - Accessible Route Tool
Changes in Level - Accessible Route Tool This handy tool was developed by Evan Terry Associates to assist its surveyors in measuring changes in level along an accessible...