The Swirl is about spinning, climbing, and gaming for kids at all levels and abilities. The trick is to control the Spinner and not be controlled by it. The three different Swirl...
Search Results "Ground Floor Exit"
- Kompan, Inc. Electronic Playgrounds - ICON1014 - Swirl
- Kompan, Inc. M172 - Horse Spring Rider
- Kompan, Inc. Racer ELE400002
- Kompan, Inc. Spinner Bowl ELE400024
- Kompan, Inc. Spinner Plate NRO110
- Kompan, Inc. NRO104 - Multi Springer Spring Toy
- TechniSoil G3® Pathway Liquid Polymer Stabilizer
- TechniSoil G3® Commercial Surface Liquid Polymer Stabilizer
-
11B-813.2.10 Door swing
Where a clear floor space complying with Section 11B-305.3 is provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space, clearance...
-
608.2.2.1 Clearance
A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. EXCEPTION: A lavatory complying...
-
Obstructions
Obstructions “Obstructions” are also prohibited by TAS 604.3.2 within the required water closet clearance. An obstruction is any element that violates the protruding object...
-
608.2.2.1 Clearance
A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. EXCEPTION: A lavatory complying...
-
608.2.2.1 Clearance
608.2.2.1 Clearance. A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. EXCEPTION:...
-
10.3.2(4)
(4) In light rail, rapid rail and commuter rail key stations, the platform or a portion thereof and the vehicle floor shall be coordinated so that the vertical difference, measured when...
-
11B-411.2.1.7.1 Assignment by keypad hall call console
The audio output shall provide verbal instruction for the user to enter a destination floor....
-
11B-411.2.1.7.1 Assignment by keypad hall call console
The audio output shall provide verbal instruction for the user to enter a destination floor....
-
11B-411.2.1.7.1 Assignment by keypad hall call console
The audio output shall provide verbal instruction for the user to enter a destination floor....
- SDC Sure Exit® PSB560 REX Pressure Sense Exit Bar
-
A4.22.3 Clear Floor Space
Figure 28 (section 4.16) provides minimum clear floor space dimensions for toilets in accessible “unisex” toilet rooms....
-
F216.1 General
Signs shall be provided in accordance with F216 and shall comply with 703. EXCEPTIONS: 1. Building directories, menus, seat and row designations in assembly areas, occupant names,...
-
703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
11B-703.1 General
Signs shall comply with Section 11B-703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
11B-703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms. [S.H. Visual character style not addressed...
-
703.1 General
Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one with visual,...