A: Yes. It is the same legal standard of "undue burden" discussed earlier with regard to the provision of communication aids. Your agency is not required to undertake alterations...
Search Results "Floor Slope"
-
21. Q: Is there a limit to the amount of money my agency must spend to alter an existing police facility?
-
T404 Level Boarding and Alighting
[See subsections ...]
-
7(2)(b)(iii)
(iii) When both tub and shower fixtures are provided in the bathroom, at least one is made accessible. When two or more lavatories in a bathroom are provided, at least one is made...
-
7(2)(b)(i)
(i) Where the door swings into the bathroom, there is a clear space (approximately, 2' 6" by 4'0") within the room to position a wheelchair or other mobility aid clear of the path of...
-
11B-407.2.3.2 Reserved
ETA Editor's Note Imposing additional requirements regarding characters and colors, the preceding CBC requirements pertaining to elevator hoistway signs are more stringent...
-
11B-407.2.3.2 Reserved
ETA Editor's Note Imposing additional requirements regarding characters and colors, the preceding CBC requirements pertaining to elevator hoistway signs are more stringent...
-
1132A.4 Level floor or landing
The floor or landing on each side of a door shall be level....
-
11B-233.3.1.2.6 Public housing facility site impracticality
The remaining ground floor residential dwelling units shall comply with the following requirements: 1. Grab bar reinforcement complying with Section 11B-609. 2. ...
-
Section F: Voting Area
_____________________________ Location name:______________________ F Within the Voting Area Yes No N/A Comments/Remedies F1 Are floor...
-
Surface and Slope [1012.4 and 1012.5]
When the surface of parking spaces and pull-up spaces for RVs is constructed of asphalt, concrete, or boards, the slope of the parking spaces and pull-up spaces must be no steeper than 1...
-
804.3 Kitchen Work Surface (Exception)
The work surface must have a clear floor space positioned for a forward approach, and knee and toe clearance beneath the kitchen counter....
- Landscape Forms Inc. Sort Recycling Units
- Magnuson Group SMOKE Waste & Ash Receptacle
-
SETTLEMENT AGREEMENT BETWEEN THE UNITED STATES OF AMERICA AND FILL BUILDING ASSOCIATES, LLC, d/b/a FILL BUILDING EAST
SETTLEMENT AGREEMENT BETWEEN THE UNITED STATES OF AMERICA AND FILL BUILDING ASSOCIATES, LLC, d/b/a FILL BUILDING EAST (DJ # 202-37-249)
-
11B-233.3.1.2.6.5 Additional requirements.
1. Grab bar reinforcement complying with Sections 11B-809.10.5.2, 11B-809.10.6.4, or 11B-809.10.7.3. 2. Interior door opening width complying with Section 11B-404.3.1. 3....
-
Attachment H
clear floor space of 30 by 48 inches that allows a forward or parallel approach by a person using a wheelchair. ...
- Figure 407.2.3.2 Car Designations on Jambs of Destination-Oriented Elevator Hoistway Entrances – Drawing from the U.S. Access Board
-
7(1)(b)
(b) Clearance between counters and all opposing base cabinets, countertops, appliances or walls is at least 40 inches.
-
7(2)(b)(ii)
(ii) Where the door swings out, a clear space is provided within the bathroom for a person using a wheelchair or other mobility aid to position the wheelchair such that the person is...
-
ADA & Level Boarding Guidance - Platform Height
49 CFR §§37.41-43; 37.9(a), (d); 49 CFR Part 37, App. A (810.5.3) DECEMBER 14, 2011
-
2. a. iv. Path-of-Travel (wheelchair) space allowances
2. a. iv. Path-of-Travel (wheelchair) space allowances.xii In general, a 36” wide accessible route is needed with a slightly larger space provided at corners. If a 180° turn is...
-
4.34.5.2 WATER CLOSETS
[See subsections ...]