11B-810.10 Track crossings
Exception: Openings for wheel flanges shall be permitted to be 2½ inches (64 mm) maximum. FIGURE 11B-810.10 (EXCEPTION) TRACK CROSSINGS...
-
Sec. 469.001(c)
persons with disabilities and to eliminate, to the extent possible, unnecessary barriers encountered by persons with disabilities whose ability to engage in gainful occupations or to achieve maximum...
-
Disinformation Corridor Exhibit
The force required to push or pull open the red door leading out of the exhibit is 15 lbf, which exceeds the maximum allowable door opening force of 5 lbf....
-
Rising Sun Exhibit
The force required to push or pull open the painted door leading out of the exhibit is 14 lbf, which exceeds the maximum allowable door opening force of 5 lbf....
-
R402.2 Protrusion Limits
Objects with leading edges more than 685 mm (2.25 ft) and not more than 2m (6.7 ft) above the finish surface shall protrude 100 mm (4 in) maximum horizontally into pedestrian circulation...
-
407.8.2.1 Unobstructed Side Reach
Where the operable part is located 10 inches (255 mm) or less beyond the vertical reference plane, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm) high...
-
704.8.1 Automatic sprinkler system
In buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1, the maximum allowable area of unprotected openings in occupancies other than Groups...
-
604.8.3 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor....
-
810.10 Track Crossings
EXCEPTION: Openings for wheel flanges shall be permitted to be 2½ inches (64 mm) maximum. Figure 810.10 (Exception) Track Crossings...
-
603.4 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor....
-
4.3.5 Transfer Height
Tent platform surfaces that are not the same elevation as the ORAR shall be between 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the floor or ground surface adjacent to...
-
R305.1.2 Dome Spacing
The truncated domes shall have a center-to-center spacing of 41 mm (1.6 in) minimum and 61 mm (2.4 in) maximum, and a base-to-base spacing of 17 mm (0.65 in) minimum, measured between the...
-
4.3.5 Transfer Height
Tent platform surfaces that are not the same elevation as the ORAR shall be between 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the floor or ground surface adjacent to...
-
7.3 CHECK-OUT AISLES
Clear aisle width shall comply with 4.2.1 and maximum adjoining counter height shall not exceed 36 in (915 mm) above the floor....
-
11B-703.5.8 Character spacing
Spacing between individual characters shall be 10 percent minimum and 35 percent maximum of character height....
-
11B-1009.6.1 Pool stairs
Exception: Pool step riser heights shall not be required to be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum provided that riser heights are uniform....
- TSA Cares: Passenger Support
-
Accessibility Engineering Specialists
This association is expected to sponsor conferences and workshops, disseminate information, and suggest course curricula for future training and certification."...
-
Design Criteria for the Transfer Station
The design criteria for the station listed in Table 1 were derived from multiple design requirements in the standards where both adults and children are expected to transfer. ...
-
502.4 Platform Accessibility Features (Section-by-Section Analysis)
502.4 Platform Accessibility Features (Section-by-Section Analysis) This section addresses specifications for capabilities that users with disabilities have come to expect as core accessibility...
-
VI. Regulatory Process Matters (SBREFA, Regulatory Flexibility Act, Executive Orders, Benefits and Costs)
., notices of proposed rulemaking or final rules) that are deemed to be economically significant regulatory actions with an annual economic impact of $100 million or more or that are expected...