Section 608.5.2 covers the current ADA Standards for controls in standard roll-in type shower compartments.
Search Results "Compartment Door"
-
Standard Roll-In Type Shower Compartments: ADA Standard Section 608.5.2
-
Alternate Roll-In Type Shower Compartments: ADA Standard Section 608.5.3
Section 608.5.3 covers the current ADA Standards for controls in alternate roll-in type shower compartments.
-
11B-809.10.4 Sufficient maneuvering space
Where doors swing into the toilet and bathing or powder rooms required to comply with Section 11B-809.10, a clear maneuvering space of 30 (762 mm) inches by 48 inches (1219 mm) minimum shall...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
- Hager Companies 4.75” Square ADA Actuator 2-659-0305
- Hager Companies 6” Round ADA Actuator 2-659-0307
- Hager Companies 6” Round ADA Actuator 2-659-0304
- Hager Companies 4.75” Round ADA Actuator 2-659-0306
- Hager Companies 4.75” Square ADA Actuator 2-659-0308
- Hager Companies 6” Round ADA Actuator 2-659-0303
-
11B-608.3.1 Transfer type shower compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (457 mm) from the control wall....
-
11B-608.3.1 Transfer type shower compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (457 mm) from the control wall....
-
Plan 6A: 12-Foot Wide Accessible Guest Room
Features include a transfer shower, water closet length (rim to rear wall) 24 inches maximum, comparable vanity, clothes closet with swinging door, and door connecting to adjacent guest...
- CRL-Blumcraft® Panic Handles 08 7100
-
11B-608.3.2 Standard roll-in type shower compartments
[2010 ADA Standards] 608.3.2 Standard Roll-In Type Shower Compartments....
-
11B-608.3.2 Standard roll-in type shower compartments
[2010 ADA Standards] 608.3.2 Standard Roll-In Type Shower Compartments....
- Stanley Access Technologies Dura-Care 7000 Manual Door System
- LaCantina Aluminum Slider System
- Door King Inc. Proximity Card Readers
- Doorbell Factory Small Rectangle Stainless Steel Doorbell
-
Amenities
Sauna doors are still required to provide access to wheelchair users. Therefore, they must provide 32 clear inches. 612 Saunas and Steam Rooms. 612.2 Bench....
-
Transfer Compartments
Seats are required in transfer compartments and roll-in showers in transient lodging guest rooms (608.4)....
- Doorbell Factory Square Stainless Steel Doorbell