Controls shall be located within one of the reach ranges specified in Section 11B-308.
Search Results "Elevator Door Timing"
-
11B-411.4.6.1 Location
-
11B-407.4.6.2.4 Operation
Car control buttons shall be activated by a mechanical motion that is detectable.
-
11B-407.4.10.3 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the support rail, fastener, mounting...
-
11B-407.4.10.1 Location
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum. Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above...
-
11B-407.4.10.2 Surfaces
Support rails shall be smooth and any surface adjacent to them shall be free of sharp or abrasive elements.
-
11B-411.4.7.1 Type
Control button type shall comply with Section 11B-407.4.7.1.1.
-
407.4.6.2.2 Arrangement
Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right.
-
407.2.2 Hall Signals
407.2.2 Hall Signals. Hall signals, including in-car signals, shall comply with 407.2.2.
-
407.4.6.2.1 Size
Buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension.
-
407.4.6.2.1 Size
407.4.6.2.1 Size. Buttons shall be ¾ inch (19 mm) minimum in their smallest dimension.
-
407.4.7.1 Buttons
Car control buttons shall comply with 407.4.7.1.
-
407.2.2 Hall Signals
Hall signals, including in-car signals, shall comply with 407.2.2.
-
407.4.6.2.2 Arrangement
407.4.6.2.2 Arrangement. Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right.
-
407.4.7.1 Buttons
407.4.7.1 Buttons. Car control buttons shall comply with 407.4.7.1.
- Hager Companies Door Pull 974B
-
Tactile and Visual Signs [ADA Standards §216.2, §216.4.1]
Tactile and Visual Signs [ADA Standards §216.2, §216.4.1] The IBC requires exits and exit access doors to be marked by illuminated exit signs (§1011, §1003.2.10)....
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
In elevator buildings, facilities with multi-story residential dwelling units shall comply with the following: The primary entry of the multi-story residential dwelling unit shall...
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
In elevator buildings, facilities with multi-story residential dwelling units shall comply with the following: The primary entry of the multi-story residential dwelling unit shall...
-
1132A.4, Item 1
., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change in height between floor surfaces....
-
1132A.4, Item 1
., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change in height between floor surfaces....
-
[F] 907.5.2.3 Visible alarms
Visible alarm notification appliances shall not be required in elevator cars....
-
§ 38.93(e) Signage
The International Symbol of Accessibility shall be displaced on the exterior of all doors complying with this section unless all cars are accessible and are not marked by the access symbol...
-
C. Toilet Rooms:
PSE shall provide at least seventeen (17) ambulatory accessible and/or 60-inch wide accessible toilet compartments with an outward swinging, self-closing door disbursed as set forth in the...
-
Verify Electrical
11B-308.1.2 Alarm/detector systems. 11B-702 Height of HVAC controls. 11B-308 Location of elevator...