(7) An elevator lobby when elevator shafts and adjacent lobbies are pressurized as required for smokeproof enclosures by local regulations and when complying with requirements herein...
Search Results "Day Use Area"
-
4.3.11.1(7)
-
4.1.3 ACCESSIBLE HOUSING
Accessible housing shall comply with the requirements of 4.1 and 4.34 except as noted below:
-
4.3.10* EGRESS
Accessible routes serving any accessible space or element shall also serve as a means of egress for emergencies or connect to an accessible place of refuge. Such accessible routes...
-
1015.5 Surface
The surface of clear ground spaces and turning spaces shall be firm and stable.
-
11B-1008.2.6.1 Accessibility
Ground surfaces shall comply with ASTM F 1951. Ground surfaces shall be inspected and maintained regularly and frequently to ensure continued compliance with ASTM F 1951.
-
Identification of available accessible seating. (Section-by-Section Analysis)
Identification of available accessible seating. In the NPRM, the Department proposed § 35.138(c), which, as modified and renumbered as paragraph (b)(3) in the final rule, requires a...
-
11B-1002.5 Amusement ride seats designed for transfer
Amusement ride seats designed for transfer shall comply with Section 11B-1002.5 when positioned for loading and unloading. [2010 ADAS] Advisory 1002.5 Amusement Ride Seats...
-
17. Exposing Vehicle to Hazards
If the passenger requests that a vehicle follow a path to a pick up or drop off point that would expose the vehicle and its occupants to hazards, such as running off the road,...
-
§ 38.29(e)
(e) For vehicles in excess of 22 feet in length with front-door lifts or ramps, vertical stanchions immediately behind the driver shall either terminate at the lower edge of the...
-
11B-247.1.2.5 Blended transitions
11B-247.1.2.5 Blended transitions. Blended transitions shall have detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.5.
-
11B-1002.5 Amusement ride seats designed for transfer
Amusement ride seats designed for transfer shall comply with Section 11B-1002.5 when positioned for loading and unloading. Advisory 11B-1002.5 Amusement ride seats designed...
-
11B-705.1.2.5 Blended transitions
11B-705.1.2.5 Blended transitions. Detectable warnings at blended transitions shall be 36 inches (914 mm) in width.
-
11B-1008.2.6.1 Accessibility
Ground surfaces shall comply with ASTM F 1951. Ground surfaces shall be inspected and maintained regularly and frequently to ensure continued compliance with ASTM F 1951.
-
221.2.3.1 Horizontal Dispersion
Horizontal dispersion shall not be required in assembly areas with 300 or fewer seats if the companion seats required by 221.3 and wheelchair spaces are located within the 2nd or 3rd quartile...
-
221.2.3.1 Horizontal Dispersion
Horizontal dispersion shall not be required in assembly areas with 300 or fewer seats if the companion seats required by 221.3 and wheelchair spaces are located within the 2nd or 3rd quartile...
-
IV. ALTERATIONS AND NEW CONSTRUCTION
The ILA shall have thirty (30) days from the date the ILA receives the ADA Plans to render a written opinion to the United States as to whether the ADA Plans comply with the ADA. ...
-
9.5.2(2)(e)
(e) at least one route connecting elements (a), (b), (c) and (d) which a person with mobility impairments can use including minimum clear width of 36 in (915 mm), passing space complying...
-
F221.2.3.1 Horizontal Dispersion
Horizontal dispersion shall not be required in assembly areas with 300 or fewer seats if the companion seats required by F221.3 and wheelchair spaces are located within the 2nd or 3rd quartile...
-
11B-407.4.1 Car dimensions
Exception: In existing buildings, where existing shaft configuration prohibits strict compliance with Section 11B-407.4.1, existing elevator car configurations that provide a clear floor area...
-
11B-407.4.1 Car dimensions
Exception: In existing buildings, where existing shaft configuration prohibits strict compliance with Section 11B-407.4.1, existing elevator car configurations that provide a clear floor area...
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
§ 36.508 Effective date.
[See subsections ...]
-
604.9.6 Dispensers
Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the...
-
§382.159 How are complaints filed with DOT?