Section 604.8.1.1 covers the current ADA Standards for the size of wheelchair accessible compartments.
Search Results "Ceramic Tile Flooring"
Commonly Searched Documents
-
Size: ADA Standard Section 604.8.1.1
-
F2
If there is a built-in reception or other type of counter, does it have a section that is at least three feet long that is no higher than 36 inches above the floor or is there a nearby surface...
-
4.19.2 HEIGHT AND CLEARANCES
Lavatories shall be mounted with the rim or counter surface no higher than 34 in (865 mm) above the finished floor....
-
4.1.2(9)
(9) If drinking fountains or water coolers are provided, approximately 50 percent of those provided on each floor shall comply with 4.15 and shall be on an accessible route....
- Neo-Metro Urban Stainless Steel Toilet 8950-3-ADA-PFS
-
11B-1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the...
-
§ 38.23(c)(5) Slope
If the height of the vehicle floor from which the ramp is deployed is 3 inches or less above a 6-inch curb, a maximum slope of 1:4 is permitted; if the height of the vehicle floor from which...
-
11B-1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
11B-1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
F217.2 Wheelchair Accessible Telephones
Table F217.2 Wheelchair Accessible Telephones Number of Telephones Provided on a Floor, Level, or Exterior Site Minimum Number of Required Wheelchair Accessible Telephones...
-
1007.2.1 Buildings with four or more stories
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
1003.2.13.1.1 Buildings with four or more stories
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground....
-
217.2 Wheelchair Accessible Telephones
Table 217.2 Wheelchair Accessible Telephones Number of Telephones Provided on a Floor, Level, or Exterior Site Minimum Number of Required Wheelchair Accessible...
-
Electronic instruments
Electronic instruments have been developed to measure floor flatness....
-
1009.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
1009.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, not less than one required accessible means of egress shall be an elevator...
-
Elevator Exemption (Preamble, Section-by-Section Analysis)
ground floor. 4....
-
Elevator Exemption (Section-By-Section Analysis and Response to Comments)
ground floor. 4....
-
12. Reach Range
Are there towel racks or bars placed within 54" of the floor for side approach or 48" of the floor for forward approach so persons who use wheelchairs can approach and use the towel racks...
-
4.19.2 Height and Clearances
Lavatories shall be mounted with the rim or counter surface no higher than 34 in (865 mm) above the finish floor....
-
11B-809.10.8.7 Mirrors and towel bars
Where mirrors are provided the bottom edge of the reflective surface shall be 40 inches (1016 mm) maximum above the finish floor....