commuter rail, and intercity rail systems subject to Department of Transportation regulation 49 CFR 37.21 where it is not operationally or structurally feasible to meet the horizontal gap or vertical...
Search Results "Vertical Actuation Bar"
-
810.5.3 Platform and Vehicle Floor Coordination
-
11B-410.8 Restriction sign
For lifts with a signed installation contract before May 1, 2008: CCR, Title 8, Section 3094 provides safety regulations for Vertical Platform (Wheelchair) Lifts....
- Mockett DH4 Slim Cylindrical Door Handle
- Mockett DH5/BB Large Cylindrical Door Handle Back to back
- Mockett DH4/BB Slim Cylindrical Door Handle Back to back
-
Re: 11B-904.3.4 Identification sign
In future, we invite you to submit a Helpdesk ticket, by using the "Feedback or Help", in dark blue next to the Search Bar!...
-
Shower/Tub Seat Mounting Location
seat is in the down position, it does put the user closer to the shower and water controls while using the shower, but if someone is standing in the shower the seat obstructs the grab bars...
- Rebuilding Together Fargo-Moorhead Area - Fargo, ND
-
5. Accessible Features
impede exterior and interior routes; snow removal on exterior routes; replacing damaged or stolen room identification signs; tightening or adjusting accessible toilet seat fasteners, grab bars...
-
O. Accessible Portable Toilets
Accessible portable toilets should similar features to a standard accessible toilet stall including an accessible door, side and rear grab bar, clear space next to the toilet, and maneuvering...
-
608.5.2 Standard Roll-In Type Shower Compartments
In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
Door Hardware [4.13.9]
Various types of hardware are acceptable although those that can be operated with a closed fist (levers, push bars) or a loose grip (pull handles) accommodate the broadest range of users...
-
604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
Construction and Manufacturing Tolerances
Grab Bar Diameter and Clearance...
-
1007.8 Exterior area for assisted rescue
This construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever is lower....
-
1003.2.13.7 Exterior area for assisted rescue
This construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever is lower....
-
A4.30.4 Raised and Brailled Characters and Pictorial Symbol Signs (Pictograms)
Vertical separation between cells .395 in....
-
Accessible Routes within a Building or Facility
Accessible vertical interior circulation must be in the same area as stairs and escalators, not isolated in the back of the facility....
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
11B-303.3 Beveled
A change in level of 1/2 inch (13 mm) is permitted to be 1/4 inch (6.4 mm) vertical plus 1/4 inch (6.4 mm) beveled....
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
- Landscape Forms Inc. MutipliCITY Path Light Illuminated Bollards
- Allegion Falcon 1690 Series Exit Devices