Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”. [2010...
Search Results "Toilet Room Signage"
Commonly Searched Documents
-
11B-703.2.4 Character proportions
-
11B-703.7.2.3 Volume control telephones
Telephones with a volume control shall be identified by a pictogram of a telephone handset with radiating sound waves on a square field such as shown in Figure 11B-703.7.2.3.
-
11B-703.7.2.2 International Symbol of TTY
The International Symbol of TTY shall comply with Figure 11B-703.7.2.2.
-
11B-703.2 Raised characters
Raised characters shall comply with Section 11B-703.2 and shall be duplicated in Braille complying with Section 11B-703.3. Raised characters shall be installed in accordance with...
-
Section 36.403 Alterations: Path of Travel (Preamble, Section-by-Section Analysis)
Paragraph (b) provides that areas such as mechanical rooms, boiler rooms, supply storage rooms, employee lounges and locker rooms, janitorial closets, entrances, corridors, and restrooms...
-
Medical Care Facilities: ADA Standard Section 232.4
Section 232.4 covers scoping requirements in the current ADA Standards for medical care facilities.
-
11B-232.4 Medical care facilities
Patient bedrooms or cells required to comply with Section 11B-223 shall be provided in addition to any medical isolation cells required to comply with Section 11B-232.3.
-
11B-809.10.6 Showers
Showers required by Section 11B-809.10 shall comply with this section.
-
11B-206.4.1 Entrances and exterior ground floor exits
Directional signage shall comply with Chapter 10, Section 1007.10. Advisory 11B-206.4.1 Entrances and exterior ground floor exits Exception. ...
-
G. Door Hardware
Is the door hardware (levers, pulls, panic bars, etc.) on all entry doors to accessible guestrooms and other passage doors within the room usable with one hand, without tight grasping, pinching...
-
224.6 Housing at a Place of Education
Housing at a place of education shall comply with the provisions applicable to transient lodging, including, but not limited to, the requirements for transient lodging guest rooms in sections...
-
Assistive Listening Systems
create listening challenges for people who are Deaf or hard of hearing, including too much distance between the listener and the sound source, competing noise in the environment, and poor room...
-
Attachment I
Women’s 1st Floor Toilet Room (outside Court Room) The toilet room sign is mounted on the door, does not contain Braille, and does not contain the International Symbol of...
-
Notification Devices: ADA Standard Section 806.3.2
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell....
-
The Presentation Area / Speaker’s Platform Design and Considerations
Both layouts incorporate presentation screens that are easily viewed from all areas of the room....
-
Swimming pools, wading pools, saunas, and steam rooms. (Section-by-Section Analysis)
Swimming pools, wading pools, saunas, and steam rooms....
-
11B-806.3.2 Notification devices
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell....
-
Accessible Entrances
Accessible Entrances One small step at an entrance can make it impossible for individuals using wheelchairs, walkers, canes, or other mobility devices to do business with you....
-
11B-216.4.2 Areas of refuge and exterior areas for assisted rescue
Signs required by Chapter 10, Section 1007.11 to provide instructions in areas of refuge shall comply with Section 11B-703.5 _|Signs; Visual Characters|_. Signs required by Chapter...
-
11B-216.4.2 Areas of refuge and exterior areas for assisted rescue
Signs required by Chapter 10, Section 1009.11 to provide instructions in areas of refuge shall comply with Section 11B-703.5 _|Signs; Visual Characters|_. Signs required by Chapter...
-
§ 38.27(c)
(c) Characters on signs required by paragraphs (a) and (b) of this section shall have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and...
-
11B-216.4.2 Areas of refuge and exterior areas for assisted rescue
Signs required by Chapter 10, Section 1009.11 to provide instructions in areas of refuge shall comply with Section 11B-703.5. Signs required by Chapter 10, Section 1009.9 at doors to...
-
Technical Memorandum TM 2012-09 Employee Break Rooms
TM 2012-09 Employee Break Rooms Effective Date: January 22, 2013 2012 TAS Reference: 212 and 804 In accordance with TAS 106.5.28, kitchenettes and break rooms are not employee...
-
Doors, Doorways, and Gates
In transient lodging facilities, doors and doorways in inaccessible guest rooms are required to provide a clear width of at least 32 inches....