The length of the transfer wall shall be 60 inches (1524 mm) minimum and shall be centered on the clear deck space....
Search Results "Door Clear Width"
-
11B-1009.4.3 Wall depth and length
-
11B-1009.4.3 Wall depth and length
The length of the transfer wall shall be 60 inches (1524 mm) minimum and shall be centered on the clear deck space....
-
1134A.4 Sufficient maneuvering space
Where the door swings into the bathroom or powder room, there shall be a clear maneuvering space outside the swing of the door of at least 30 inches by 48 inches (762 mm by 1219 mm) within...
-
1134A.4 Sufficient maneuvering space
Where the door swings into the bathroom or powder room, there shall be a clear maneuvering space outside the swing of the door of at least 30 inches by 48 inches (762 mm by 1219 mm) within...
-
11B-809.10.7.1 Floor space
Exception: The 48-inch (1219 mm) minimum clear width may be reduced to 36 inches (914 mm) minimum for lavatories, cabinets, wing walls, or privacy walls located immediately adjacent to a...
-
11B-809.10.7.1 Floor space
Exception: The 48-inch (1219 mm) minimum clear width may be reduced to 36 inches (914 mm) minimum for lavatories, cabinets, wing walls, or privacy walls located immediately adjacent to a...
-
Problem Four (Entrance)
Problem Four: The entrance door has a door knob and/or latch that requires tight pinching and twisting and is not accessible....
-
11B-813.2.1.2 Clearance
A 36 inches minimum (914 mm) width side clearance shall be provided along the entire length of one side of adult changing tables....
-
11B-813.2.1.2 Clearance
A 36 inches minimum (914 mm) width side clearance shall be provided along the entire length of one side of adult changing tables....
-
Clear Deck Space
Clear Deck Space Clear deck space must be provided to enable a person to get close enough to the pool lift seat to easily transfer from a wheelchair or mobility device....
- Landscape Forms Inc. Austin Trash Receptacle
- Aurora Doors Sliding Barn Door
-
4.7.8 Utility and Dump Station Hookup Clear Floor or Ground Space
The clear floor or ground space around utility and dump station hookups shall be at least 30 inches (760 mm) by 60 inches (1525 mm)....
-
1134A.4 Sufficient maneuvering space
Where the door swings into the bathroom or powder room, there shall be a clear maneuvering space outside the swing of the door of at least 30 inches by 48 inches (762 mm by 1219 mm) within...
-
1134A.8, Item 2
A clear maneuvering space at least 30 inches by 48 inches (762 mm by 1219 mm) shall be provided at lavatories and shall be centered on the lavatory....
-
1134A.8, Item 2
A clear maneuvering space at least 30 inches by 48 inches (762 mm by 1219 mm) shall be provided at lavatories and shall be centered on the lavatory....
- SOSS Door Hardware UltraLatch Demonstration Video
- DORMA ED100/250 Swing Door Operator
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
1009.4.3 Wall Depth and Length
The length of the transfer wall shall be 60 inches (1525 mm) minimum and shall be centered on the clear deck space. Figure 1009.4.3 Depth and Length of Transfer Walls...
-
11B-1009.4.3 Wall depth and length
The length of the transfer wall shall be 60 inches (1524 mm) minimum and shall be centered on the clear deck space. FIGURE 11B-1009.4.3 DEPTH AND LENGTH OF TRANSFER WALLS...