Sec. 469.102. Procedure for Submitting Plans and Specifications
-
703.5.7 Stroke Thickness
703.5.7 Stroke Thickness. Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character.
-
703.4 Installation Height and Location
703.4 Installation Height and Location. Signs with tactile characters shall comply with 703.4.
-
11B-703.4 Installation height and location
Signs with tactile characters shall comply with Section 11B-703.4.
-
4.30.4* Raised and Brailled Characters and Pictorial Symbol Signs
4.30.4* Raised and Brailled Characters and Pictorial Symbol Signs (Pictograms). Letters and numerals shall be raised 1/32 in, upper case, sans serif or simple serif type and shall be...
-
Finish and Contrast [4.30.5]
Finish and Contrast [4.30.5] All signs covered by 4.30 must have a non-glare finish, such as matte or eggshell. Recommendations: An eggshell finish is recommended. Consideration...
-
A4.1.3(19)(a)
A4.1.3(19)(a) Readily removable or folding seating units may be installed in lieu of providing an open space for wheelchair users. Folding seating units are usually two fixed seats...
-
Mounting Location and Height [4.30.6]
Mounting Location and Height [4.30.6] Placement of tactile signs aside doors (latch-side) provides safety since locating signs on doors that swing out is hazardous. It also...
-
4.1.2(15)
(15) If signs are provided, they shall comply with 4.30.1, 4.30.2 and 4.30.3. In addition, permanent signage that identifies rooms and spaces shall also comply with 4.30.4 and...
-
4.30.4* RAISED CHARACTERS OR SYMBOLS
Letters and numbers on signs shall be raised 1/32 in (0.8 mm) minimum and shall be sans serif characters. Raised characters or symbols shall be at least 5/8 in (16 mm) high, but no...
-
11B-703.4 Installation height and location
11B-703.4 Installation height and location. Signs with tactile characters shall comply with Section 11B-703.4.
-
11B-703.5.7 Stroke thickness
11B-703.5.7 Stroke thickness. Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADAS] 703.5.7...
-
11B-703.5.7 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADA Standards] 703.5.7 Stroke Thickness....
-
11B-703.4 Installation height and location
Signs with tactile characters shall comply with Section 11B-703.4.
-
Re: 703 Signs
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
- Innerface Clearview Interior Signage
- Innerface ARQ Interior Sign Frame System
-
Section 35.160 Communications (Section-by-Section Analysis)
the public with disabilities, but to their companions as well....
-
General: ADA Standard Section 210.1
Section 210.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for stairways.
- Grants for Home Modification: 16 Resources for Homeowners with Disabilities
-
§ 35.150(b)(2) Safe harbor
If a public entity has constructed or altered elements in an existing facility in accordance with the specifications in either the 1991 Standards or the Uniform Federal Accessibility Standard...
- DOE "Dear Colleague" Letter: and Resource Guide on Students with ADHD (July 26, 2016)
-
Armor-Tile Tactile Systems Cast In Place
Requires the Premium User plan or above. (Login or upgrade your account!)
-
ADA Solutions, Inc. Radius Tactile Systems; Part# 24RADRET
Requires the Premium User plan or above. (Login or upgrade your account!)