Clear floor spaces 30 inches (762 mm) by 48 inches (1219 mm), with centerlines aligned with the centerline of the work surface, appliance, sink or fixture, shall be provided in the following...
Search Results "Perpendicular Parking Space"
-
11B-809.9.1 Clear floor space
-
11B-809.9.1 Clear floor space
Clear floor spaces 30 inches (762 mm) by 48 inches (1219 mm), with centerlines aligned with the centerline of the work surface, appliance, sink or fixture, shall be provided in the following...
-
11B-304.4 Door swing
Doors shall be permitted to swing into turning spaces....
-
304.4 Door Swing
Doors shall be permitted to swing into turning spaces....
-
11B-304.4 Door swing
Doors shall be permitted to swing into turning spaces....
-
11B-304.4 Door swing
Doors shall be permitted to swing into turning spaces....
-
304.4 Door Swing
Doors shall be permitted to swing into turning spaces....
-
304.4 Door Swing
Doors shall be permitted to swing into turning spaces....
-
11B-805.2.3 Turning space
Turning space complying with Section 11B-304 shall be provided within the room....
-
11B-805.2.3 Turning space
Turning space complying with Section 11B-304 shall be provided within the room....
-
11B-805.2.3 Turning space
Turning space complying with Section 11B-304 shall be provided within the room....
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
6.6
6.6 In all auditoria with more than 300 seats, wheelchair spaces shall be provided in more than one location....
-
10.1 Q. Is it necessary to have an accessible path of travel from a subterranean garage to single-story covered multifamily dwellings built on top of the garage?
The below grade parking garage is a public and common use facility. Therefore, there must also be an accessible route from this parking area to the covered dwelling units....
-
DSA Drawing 11B-406-5 Perpendicular Curb Ramp next to a Curb and Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
6.7
6.7 Cinemark shall provide at least the minimum number of wheelchair spaces required in each auditorium as set forth in § 4.1.3(19)(a) of the ADA Standards....
-
7.4.5.3 Non-complying Segment Ends
Where a segment of the trail does not comply with 7.4, a passing space shall be located at the end of each adjacent trail segment that does comply with 7.4....
-
1008.2.6 Ground Surfaces
Ground surfaces on accessible routes, clear floor or ground spaces, and turning spaces shall comply with 1008.2.6. Advisory 1008.2.6 Ground Surfaces....
-
Start of Play Areas
Start of Play Areas The clear floor or ground space area at the start of play for each accessible hole must be 48 by 60 inches minimum to allow players to position themselves for the...
-
Call Button Clear Floor Space
...are all of the elevator lobbies free of ash trays or other elements placed below the elevator call buttons that project more than 4"? [ADA Stds. 4.10.3] Yes __ No __ N/A __...
-
802 Wheelchair Spaces, Companion Seats, and Designated Aisle Seats
Section 802 provides requirements for wheelchair spaces, companion seats, and designated aisle seats in assembly areas. Requirements have been reorganized and renumbered....