Stations covered by this section shall have identification signs complying with Section 11B-703.5 _|Signs; Visual Characters|_....
Search Results "Character Height (Visual)"
-
11B-810.6.3 Station names
-
11B-703.6.1 Pictogram field
Pictograms shall have a field height of 6 inches (152 mm) minimum. Characters and Braille shall not be located in the pictogram field. Advisory 11B-703.6.1 Pictogram field. ...
-
Water Closet Centerline and Seat Height
Water closets are to be located so that the centerline is 16 to 18 inches from the side wall compartment partition (604.2). Water closets can be located so that this dimension is met...
-
4.2.4 Height of Fire-Building Surface
The fire-building surface within a fire ring shall be at least 9 inches (230 mm) above the floor or ground.
-
1011.5.2 Riser height and tread depth
... Exceptions: 4. See California Fire Code Chapter 11 and California Existing Building Code for the replacement of existing stairways. [DSA-AC] For applications listed in...
-
1136A.2 Switch and control heights
Controls or switches intended to be used by the occupant of the room or area to control lighting and receptacle outlets, appliances, alarms or cooling, heating and ventilating...
-
1136A.2 Switch and control heights
Controls or switches intended to be used by the occupant of the room or area to control lighting and receptacle outlets, appliances, alarms or cooling, heating and ventilating...
-
1011.5.2 Riser height and tread depth
... Exceptions: 4. See California Fire Code Chapter 11 and California Existing Building Code for the replacement of existing stairways. [DSA-AC] For applications listed in...
- Spectrum Industries Inc. Freedom One Sit-to-Stand Lectern™
-
25.1 Q. It appears from Figure 2(c) of the Guidelines (under Requirement 5) that there is a 34 inch height requirement for kitchen counters and vanities. Is this true?
Because the picture was taken directly from the ANSI A117.1 1986 standard, the diagram also shows the height of the obstruction, which, in this picture, is a countertop....
-
1117B.5.3
Characters on signs shall be selected from fonts that have a width-to-height ratio of between 3:5 (60 percent) and 1:1 (100 percent) measured by the width of the uppercase letter "O" and...
-
809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
Car Controls [4.10.12]
Alignment for a side reach is often difficult at panels on the front of cars due to the limited maneuvering space; consider a maximum height of 48 inches for panels on the front of cars....
-
Car Position Indicators [§407.4.8]
Specifications include: ½” min. character height Illumination of each floor level passed or stopped at Automatic verbal announcement of stop or non-verbal audible...
-
11B-809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
11B-809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
11B-809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
Miscellaneous Elements
MISCELLANEOUS ELEMENTS Fire alarm systems: visible alarms 11B-215, 11B-702 Assistive Listening...
-
Miscellaneous Elements
MISCELLANEOUS ELEMENTS Fire alarm systems: visible alarms 11B-215, 11B-702 Assistive Listening...
-
Area of Refuge Identification [IBC §1007.6.5 (2003), §1003.2.13.5.5 (2000)]
Both the IBC and the ADA Standards apply requirements for tactile and visual characters to the area of refuge signs....
-
1009.11 Instructions
Signage shall comply with Chapter 11A, Section 1143A or Chapter 11B, Section 11B-703.5 requirements for visual characters....
-
Operable Parts of Windows
Scoping provisions in 203.9 exempt employee work areas from the guidelines except for requirements concerning accessible routes, circulation paths, and wiring for visual alarms....