Exception: The clear width of 48 inches (1220 mm) between handrails is not required at stairways serving buildings equipped throughout with an automatic sprinkler system installed in accordance...
Search Results "Vacated Building"
Commonly Searched Documents
-
1009.7.4 Stairways
-
1.9.1.2 Application
accommodations, as defined, and commercial facilities, as defined, shall be accessible to persons with disabilities as follows: Exception: Certain types of privately funded multistory buildings...
-
SECTION 1011 STAIRWAYS
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for applications...
-
11B-403.6 Handrails
Handrails provided in elevator cabs and platform lifts, referred to as support rails in the California Building Code, are not required to comply with the requirements for handrails on walking...
-
SECTION 1010 DOORS, GATES AND TURNSTILES
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for applications...
-
11B-233.3.1.2.6.4 Test number three, unusual characteristics test
An accessible route to a building entrance is impractical due to unusual characteristics of the site when: 1....
-
CHAPTER 35 REFERENCED STANDARDS
To see the entire Chapter, consult California Code of Regulations, Title 24, Part 2 - 2022 California Building Code (2022 CBC), available for purchase from International Code Council (http...
-
Issue 13: How can energy codes and LEED™ “Points” be made compatible with lighting design criteria that accommodate low vision persons?
Our federal building was lit up outside like the 4th of July, and with rolling blackouts, that’s what we were doing....
-
BACKGROUND
The parties to this Settlement Agreement ("Agreement") are the United States of America (the "United States") and the Fill Building Associates, LLC, d/b/a Fill Building East ("FBE"), owner...
- HEWI Panic Bar EN 1125
-
§ 36.606(a)(2)
(2) For example, if certain equipment is not covered by the code, the determination of equivalency cannot be used as evidence with respect to the question of whether equipment in a building...
-
SECTION 1012 HANDRAILS
SECTION 1012 HANDRAILS [DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility...
-
SECTION 1009 STAIRWAYS
SECTION 1009 STAIRWAYS [DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility...
-
SECTION 1017 AISLES
SECTION 1017 AISLES [DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is...
-
1.9.1.2
accommodations, as defined and commercial facilities, as defined, shall be accessible to persons with disabilities as follows: Exception: Certain types of privately funded multistory buildings...
-
12204(c)(2) Sites eligible for listing in national register
.-- With respect to alterations of buildings or facilities that are eligible for listing in the National Register of Historic Places under the National Historic Preservation Act (16 U.S.C...
-
1007.7.6 Stairway
Exception: The clear width of 48 inches (1219 mm) between handrails is not required at stairways serving buildings equipped throughout with an automatic sprinkler system installed in accordance...
-
Technically Infeasible
With respect to an alteration of a building or a facility, something that has little likelihood of being accomplished because existing structural conditions would require removing or altering...
-
Definition [F106.5]
Pedestrian routes that are developed primarily to connect accessible elements, spaces, and buildings within a site are not a trail....
-
ADA Standards
ADA Standards - Appendix A to 28 CFR Part 36 (the ADA Regulations issued by DOJ), it is sometimes called the ADA Accessibility Guidelines for Buildings and Facilities (ADAAG)....
-
907.2.4 Group F
Exception: Manual fire alarm boxes are not required if the building is equipped throughout with an automatic sprinkler system and the notification appliances will activate upon sprinkler...
-
12204(c)(2) Sites eligible for listing in National Register
(2) Sites eligible for listing in National Register With respect to alterations of buildings or facilities that are eligible for listing in the National Register of Historic Places under...
-
E. Key Reach Range
If there is key card controlled door hardware on building entrances, is the key card reader positioned so persons who use wheelchairs may approach and operate the opener (48" high maximum...
-
12162(e)(1) New stations
(1) New stations It shall be considered discrimination for purposes of section 12132 of this title and section 794 of title 29 for a person to build a new station for use in intercity...