It should be noted that although side access to the wheelchair space is allowed, companion seating in compliance with Section 11B-802.3 must also be provided adjacent to each wheelchair...
Search Results "Transfer Side"
Commonly Searched Documents
-
11B-802.1.2 Width
-
Section 8 References
An expert review of the scientific literature on independent wheelchair transfers. Disability and Rehabilitation: Assistive Technology, January 2012; 7(1): 20–29, p. 28...
-
26.1 Q. Is a parallel approach required at the shower, as shown in Figure 7(d) of the Guidelines?
Thus the parallel approach as shown in Figure 7(d) is essential in order to be able to transfer from the wheelchair to the shower seat....
-
GRAB BAR
A grab bar may also provide support for a user transferring from a wheelchair onto a bench, seat or plumbing fixture.◼...
-
GRAB BAR
A grab bar may also provide support for a user transferring from a wheelchair onto a bench, seat or plumbing fixture. ◼...
-
407.12 Reach Height (Section-by-Section Analysis)
Specifically, this section would establish requirements for position (i.e., vertical reference plane), forward reach, and side reach....
-
R305.1.3 Contrast
Visual contrast may be provided on the full surface of the curb ramp but should not extend to flared sides....
-
References
Preserving transfer independence among individuals with spinal cord injury. Spinal Cord. 2000;38(11):649-57. 4. Gagnon D, Nadeau S, Noreau L, Eng J, Gravel D....
-
11B-705.1.2.2 Curb ramps
Detectable warnings shall extend the full width of the ramp run less 2 inches (51 mm) maximum on each side, excluding any flared sides....
-
604.5.2 Rear Wall
The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
11B-705.1.2.2 Curb ramps
Detectable warnings shall extend the full width of the ramp run less 2 inches (51 mm) maximum on each side, excluding any flared sides....
-
11B-805.4.3 Turning space
A minimum of a 36-inch wide access shall be provided to and along each side of the bed, exam table, procedure table, gurney, lounge chair and/or equipment/apparatus. ...
- Zurn Industries Stop and Supply Protector
- Zurn Industries Offset Drain Protector
- Zurn Industries Combination Kit: One Trap Protector and One Supply Stop Protector
- Hoyer Presence Heavy-Duty Lift
-
1133B.2.4.2
Regardless of the occupant load, there shall be a floor or landing on each side of a door. 1133B.2.4.2 Maneuvering clearances at doors. ...
-
M101.2 Application
Sections M301 through M304 shall be applied to diagnostic equipment, based on the patient positions that the equipment supports, during patient transfer and diagnostic use....
-
E. Level Surface
.: wheelchairs, walkers or crutches) can make convenient transfers? [ADA Stds. 4.6.3] Yes __ No __ N/A __ Comments: ___________________________________________...
-
F. Grab Bars
Does each accessible toilet have a horizontal grab bar on the wall behind the toilet that is at least 36" long and between 33"-36" above the floor for stabilization and assistance during transfer...
-
12162(a)(4)(A)(i)(III)
passenger wishes to remain in a wheelchair), or space to store and fold a wheelchair is available in the dining car at the time such passenger wishes to eat (if such passenger wishes to transfer...
-
12162(a)(3)(A)(ii)(II)
(II) to fold and store wheelchairs (to accommodate individuals who wish to transfer to coach seats) equal to not less than the total number of single-level rail passenger coaches in such...
-
Seat [4.21.3]
The seat must extend the full depth of the transfer stall to help minimize the gap between the seat and a wheelchair. Folding seats can be used....
-
Curbs [4.21.7]
This height limit also allows wheelchair footrests to clear the curb so that a person using a wheelchair can partially pull into the stall for transfer to the seat....