Does each accessible toilet have a horizontal grab bar on the wall behind the toilet that is at least 36" long and between 33"-36" above the floor for stabilization and assistance during...
Search Results "Toilet Building"
Commonly Searched Documents
-
F. Grab Bars
-
Flush Controls [4.16.5]
Flush Controls [4.16.5] Flush valve controls must be mounted no more than 44 inches above the floor on the wide side of the toilet so that they are within reach from the available clear...
-
General: ADA Standard Section 230.1
Section 230.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for two-way communication systems.
- ADA Veracity ADA Pro Application
-
GRADE (Adjacent Ground Elevation)
[DSA-AC] The lowest point of elevation of the finished surface of the ground, paving or sidewalk within the area between the building and the property line or, when the property line is...
-
604.6 Flush Controls
If plumbing valves are located directly behind the toilet seat, flush valves and related plumbing can cause injury or imbalance when a person leans back against them....
-
604.6 Flush Controls
If plumbing valves are located directly behind the toilet seat, flush valves and related plumbing can cause injury or imbalance when a person leans back against them....
-
604.6 Flush Controls
If plumbing valves are located directly behind the toilet seat, flush valves and related plumbing can cause injury or imbalance when a person leans back against them....
-
Safe Harbors
A primary entrance to the building or facility, 2. Toilet and bathing facilities serving the area, 3. Drinking fountains serving the area, 4....
-
Safe Harbor
A primary entrance to the building or facility, 2. Toilet and bathing facilities serving the area, 3. Drinking fountains serving the area, 4. ...
-
Neo-Metro Contour Commercial Toilet 8955 Series Model
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Lavatories and Mirrors [4.19]
Lavatories and Mirrors [4.19] If lavatories are provided, at least one lavatory in accessible toilet rooms and bathrooms must be accessible....
-
11B-230.1 General
Where a two-way communication system is provided to gain admittance to a building or facility or to restricted areas within a building or facility, the system shall comply with Section 11B...
-
11B-604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404, except that if the approach is to the latch side of the compartment door, clearance between the door...
-
11B-604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404, except that if the approach is to the latch side of the compartment door, clearance between the door...
-
RECOMMENDATIONS
Provide a minimum 24" clearance between any obstruction (e.g., sidewall) and the side of the toilet seat....
-
11B-805.4 Examination, diagnostic and treatment rooms
Toilet rooms that are accessed from an examination, diagnostic or treatment room shall also be accessible....
-
1.1.11 Format
This part fundamentally adopts the International Building Code by reference on a chapter-by-chapter basis....
- Bobrick Two-Wall Toilet Compartment Grab Bar Peened B-6897.99
- Bobrick Two-Wall Toilet Compartment Grab Bar Peened B-5897.99
-
Location
The ADAAG L-shaped grab bar configuration that includes a bar on the sidewall and one on the rear wall behind the toilet was consistently considered inadequate to meet the needs of people...
-
Activation: ADA Standard Section 809.5.1.2
All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the portion...
-
11B-809.5.1.2 Activation
All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the portion...