The guidelines specify that LULA elevator cars be at least 42 inches wide and 54 inches deep with a door on the narrow end providing at least 32 inches clear width (408.4.1)....
Search Results "Clear"
-
LULA Elevator Dimensions
-
M9
[ADA Standards § 4.19.2] Yes No Notes: 1. 48-inch minimum by 66-inch minimum clear floor space for toilet 2. 48-inch minimum by 30-inch minimum clear floor space...
-
304.3.2 T-Shaped Space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....
-
304.3.2 T-Shaped Space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....
-
1015.3 Viewing Space
This section requires each distinct viewing location to provide a viewing space adjacent to the clear ground space required by 1015.2 through which the point of interest is viewable....
-
1133A.7 Knee and toe space
Knee and toe space, when required by Section 1133A, shall comply with Section 1138A.2 and the following: The knee and toe space shall be clear and unobstructed, or removable base cabinets...
-
304.3.2 T-Shaped Space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....
-
1004 Exercise Machines
This section requires clear floor space for transfer to, or use of, exercise machines....
-
4.8.4(2)
(2) The landing length shall be a minimum of 60 in (1525 mm) clear....
-
Automatic Door Break Out Openings
The 2010 Standards at sections 404.1, 404.3, 404.3.1, and 404.3.6 require automatic doors that are part of a means of egress and that do not have standby power to have a 32-inch minimum clear...
-
1132A.3 Width and height of interior doors and secondary exterior doors
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
R210 Protruding Objects
Objects along or overhanging any portion of a pedestrian circulation path shall comply with R402 and shall not reduce the clear width required for pedestrian access routes....
-
Transit Shelters (R308.2) (Section-by-Section Analysis)
A clear space (see R404) must be provided entirely within the transit shelter....
-
11B-904.4 Sales and service counters
the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with Section 11B-904.4.1 provided that the required clear...
-
11B-904.4 Sales and service counters
the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with Section 11B-904.4.1 provided that the required clear...
-
405.7.3 Length
The landing clear length shall be 60 inches (1525 mm) long minimum....
-
4. Desk with knee and toe space
Desk with knee and toe space and clear floor space for front approach....
-
11B-405.7.3 Length
The landing clear length shall be 60 inches (1524 mm) long minimum....
-
5.3.2.2 Surface
The surface of the turning space and clear floor or ground space shall be firm and stable....
-
1015.5 Surface
This section requires the surface of the clear ground space and turning space to be firm and stable....
-
11B-405.7.3 Length
The landing clear length shall be 60 inches (1524 mm) long minimum....
-
11B-405.7.3 Length
The landing clear length shall be 60 inches (1524 mm) long minimum....
-
405.7.3 Length
The landing clear length shall be 60 inches (1525 mm) long minimum....
-
11B-1009.2.6 Footrests and armrests
The armrest positioned opposite the water shall be removable or shall fold clear of the seat when the seat is in the raised position. [2010 ADAS] 1009.2.6 Footrests and Armrests. ...