Transfer type shower compartments shall be permitted in transient lodging guest rooms, multi-bedroom housing units in undergraduate student housing and residential dwelling units; and shall...
Search Results "Transfer Wall"
Commonly Searched Documents
-
11B-213.3.6 Bathing facilities
-
7(2)(b)(v)
(v) Vanities and lavatories are installed with the centerline of the fixture a minimum of 1'3" horizontally from an adjoining wall or fixture....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
Standard Units
Recessing units in alcoves, wing walls, or other means of providing a detectable leading edge at or below 27 inches are acceptable....
-
Maneuvering Clearances [§404.2.4]
Such doors are usually wider to accommodate beds and gurneys, and they are often located close to adjacent interior walls to facilitate circulation and to enhance privacy. ...
-
What types of electrical or communication receptacles are exempt because they serve a “dedicated use”?
Electrical receptacles serving a dedicated use include those installed for appliances, including refrigerators, ranges, and dishwashers, and wall clocks....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
1115B.3.2, Item 3
The centerline of the water closet fixture shall be18 inches (457 mm) from the side wall or partition....
-
ASME
This document does not permit the use of inclined stairway chairlifts which do not provide platforms because such lifts require the user to transfer to a seat....
-
11B-502.4 Floor or ground surfaces
Access aisles are required to be nearly level in all directions to provide a surface for wheelchair transfer to and from vehicles. The exception allows sufficient slope for drainage....
-
3.3 Data Sources
Early on, it became clear that some Committee members were unfamiliar with issues raised during transfers from a wheelchair or scooter onto a surface such as an examination table....
-
11B-502.4 Floor or ground surfaces
Access aisles are required to be nearly level in all directions to provide a surface for wheelchair transfer to and from vehicles. The exception allows sufficient slope for drainage....
-
11B-502.4 Floor or ground surfaces
Access aisles are required to be nearly level in all directions to provide a surface for wheelchair transfer to and from vehicles. The exception allows sufficient slope for drainage....
- Trench Drain SSB 5038TR .75 Base
-
National Register of Historic Places
and other publications Help qualified historic properties receive preservation benefits and incentives Manage the National Historic Lighthouse Preservation Program that transfers...
-
505.10.2 Top Extension at Stairs
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
7(2)(a)
(a) Bathrooms that have reinforced walls for grab bars (see Requirement 6) would meet section 100.205(c)(3)(iv) if: Note: Cabinets under lavatories are acceptable provided the bathroom...
-
Extensions
Handrails that are not continuous must have horizontal extensions at both the top and bottom of the ramp at least 12 inches long that are rounded or returned smoothly to walls, posts, or...
-
11B-404.2.4.3 Recessed doors and gates
A door can be recessed due to wall thickness or because of the placement of casework and other fixed elements adjacent to the doorway....
-
11B-604.6 Flush controls
To prevent causing injury or imbalance, the plumbing can be located behind walls or to the side of the toilet; or if approved by the local authority having jurisdiction, provide a toilet...
- Sorenson Video Relay Service ntouch® PC
-
TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (hours)
HT Ad B Structural framea Including columns, girders, trusses 3b 2b 1 0 1 0 HT 1 0 Bearing walls...
-
903.3.1.1.1 Exempt locations
Generator and transformer rooms separated from the remainder of the building by walls and floor/ceiling or roof/ceiling assemblies having a fire-resistance rating of not less than 2 hours...