Waiting rooms shall comply with Section 11B-805.3....
Search Results "Toilet Room Door"
-
11B-805.3 Waiting rooms
-
Bobrick Toilet Tissue Dispenser B-699
Requires the Premium User plan or above. (Login or upgrade your account!)
-
7c.
Is there clear maneuvering floor space in front of each accessible door (see Figure 25 in the appendix for measurements) and on the pull side, is there at least 18 inches clear floor space...
-
11B-809.8.4 Door signal devices
Every primary entrance to a residential dwelling unit with adaptable features shall be provided with a door buzzer, bell, chime or equivalent....
-
4.3.11.1(6)
Doors in the smoke barrier shall be tight-fitting smoke- and draft-control assemblies having a fire-protection rating of not less than 20 minutes and shall be self-closing or automatic closing...
- S.10 All Aluminum Lift & Slide Door System Corner Detail
- S.12 Solid Wood Lift & Slide Door System Corner Detail
- Panda TS.83 Thermally Broken Multi-Slide Door System
- Panda S.81 All Aluminum Multi-Slide Door System
- Panda TS.19 Thermally Broken Lift & Slide Door System
- Panda S.12 Solid Wood Lift & Slide Door System
- S.66 Solid Wood Folding Door System Corner Detail
- Panda S.74 Aluminum Wood Clad Folding Door System
- Set Up and Adjustment of a PDQ Door Closer
-
Clear Width [4.13.5] and Vertical Clearance
Clear Width [4.13.5] and Vertical Clearance The clear width of the opening is measured from the face of the door in a 90 degrees open position to the opposite stop....
-
Size: ADA Standard Section 604.8.1.1
Section 604.8.1.1 covers the current ADA Standards for the size of wheelchair accessible compartments.
-
Re: Rockwood Manufacturing Company BFM687 BFM Series Men's ADA Toilet Room Molded Plastic Sign
THIS SIGN DOES NOT APPEAR TO MEET CURRENT STANDARDS (BOLD FONT FAILS 703.2.6) THE LINK TO THE CUT SHEET IS BROKEN (SIGN MAY NOT BE AVAILABLE)
-
Re: Rockwood Manufacturing Company BFM688 BFM Series Women's ADA Toilet Room Molded Plastic Sign
THIS SIGN DOES NOT APPEAR TO BE COMPLIANT FONT (BOLD FAILS 703.2.6) LINK ON PAGE TO CUTSHEET IS BROKEN - SIGN MAY NOT BE AVAILABLE
-
409.3.1 Power Operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in...
- Spectrum Industries Inc. Freedom XRS Elite Lectern™ Adjustable Height Lecterns
-
Thresholds [§404.2.5]
These requirements apply to all types of doors required to comply, including sliding doors. Threshold Profile...
-
5.3.4 Grab Bars
Where walls or partitions are provided, grab bars complying with ABAAS section 604.5 shall be provided. Exception: Where the walls or partitions cannot support the force...
-
4.17.4 Toe Clearances
In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor. If the depth of the stall is greater...
-
4.17.4 TOE CLEARANCES
In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor. If the depth of the stall is greater...