(5) With respect to facilities built before March 15, 2012, the requirements in this section for accessible means of entry for swimming pools, wading pools, and spas, as set forth in sections...
Search Results "Ramped Entry"
-
§ 36.304(g)(5)
-
United States of America v. Humboldt County, California - Settlement Agreement
Press Release IN THE UNITED STATES DISTRICT COURT NORTHERN DISTRICT OF CALIFORNIA SAN FRANCISCO DIVISION UNITED STATES OF AMERICA, Plaintiff, v. HUMBOLDT...
-
United States of America v. Humboldt County, California - Consent Decree
Press Release IN THE UNITED STATES DISTRICT COURT NORTHERN DISTRICT OF CALIFORNIA SAN FRANCISCO DIVISION UNITED STATES OF AMERICA, Plaintiff, v. HUMBOLDT...
- Liberty Resources, Inc - Philadelphia and Allentown, PA
-
11B-809.7.2 Changes in level
Ramps complying with Section 11B-405, elevators complying with Section 11B-407 or platform lifts complying with Section 11B-410 shall be provided where changes in level exceed 1/2 inch (...
-
11B-809.7.2 Changes in level
Ramps complying with Section 11B-405, elevators complying with Section 11B-407 or platform lifts complying with Section 11B-410 shall be provided where changes in level exceed 1/2 inch (...
-
11B-406.5.8 Counter slope
Counter slopes of adjoining gutters and road surfaces immediately adjacent to and within 24 inches (610 mm) of the curb ramp shall not be steeper than 1:20....
-
Employee Work Area - Reasoning Behind Code?
Why not just require “approach, entry & exit” like other EWAs?...
-
1132A.4, Item 5
In buildings containing covered multifamily dwelling units, the floor or landing immediately outside the entry may be sloped up to ¼ inch (6.35 mm) per foot (12 inches) (305 mm), in a direction...
-
11B-203.13 Raised boxing or wrestling rings
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
6.3(1)
EXCEPTION: Entry doors to acute care hospital bedrooms for in-patients shall be exempted from the requirement in 4.13.6 for maneuvering space at the latch side of the door if the door is...
-
1132A.4, Item 5
In buildings containing covered multifamily dwelling units, the floor or landing immediately outside the entry may be sloped up to ¼ inch (6.35 mm) per foot (12 inches) (305 mm), in a direction...
-
11B-203.13 Raised boxing or wrestling rings
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
11B-203.13 Raised boxing or wrestling rings
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
F105.2.2 ASME
standard includes additional provisions for runway enclosures, electrical equipment and wiring, structural support, headroom clearance (which is 80 inches minimum), lower level access ramps...
-
406.2 Counter Slope
Counter slopes of adjoining gutters and road surfaces immediately adjacent to the curb ramp shall not be steeper than 1:20....
-
ACCESSIBLE ROUTE
Interior accessible routes may include corridors, floors, ramps, elevators, lifts, and clear floor space at fixtures....
-
B. NOTIFICATION
Within thirty (30) days of the entry of this Consent Decree, the County will adopt and follow the attached Notice under the Americans with Disabilities Act, Attachment A (“Notice”)...
-
Employee Work Areas [§206.2.8]
However, these types of employee work areas still must be accessible for “approach, entry, and exit” (§203.9)....
-
11B-206.7.9 Team or player seating
While the use of platform lifts is allowed, ramps are recommended to provide access to player seating areas serving an area of sport activity. ◼...
-
11B-206.7.9 Team or player seating
While the use of platform lifts is allowed, ramps are recommended to provide access to player seating areas serving an area of sport activity. ◼...
-
4.7.11 Islands
Any raised islands in crossings shall be cut through level with the street or have curb ramps at both sides and a level area at least 48 in (1220 mm) long between the curb ramps in the part...
-
11B-203.14 Raised diving boards and diving platforms
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
1132A.4, Item 1
., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change in height between floor surfaces....